Variable Name: DEV_IDX_S2PVRange_Obj_Low_TE
Variable ID: 0x4550
Variable Label: Range Low
Variable Help: If Measurement Type is Conductivity, set Range Low between (0.0 to 20000.0 * Cell Constant)µS/cm or (0.0 to 20.0 * Cell Constant)mS/cm If Measurement Type is Concentration, set Range Low between 0 to 2000, Max limit is set by Conc. Curve Table If Measurement Type is Resistivity, set Range Low 0 to 20.0 MOhm-cm
Variable Handling: R/W
Variable Class: Correction
Variable Size: 4
Variable DataType: Float
Variable Display Format: |en|.3f
Variable Edit Format:
Variable Unit:
Variable Max:
Variable Min:
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
237 | 46E9 | Read_TE_Configuration |
Variable Write Command List
Command Number | Command ID | Command Name |
---|---|---|
238 | 46EA | Write_TE_Configuration |