Variable Name: var_dd_fLSThreshold
Variable ID: 0x41C8
Variable Label: Threshold
Variable Help: Threshold Displays the current switching threshold (alarm threshold for the level). The time constant is calculated automatically (factory setting), but can also be manually set to a fixed percentage value (Evaluation Mode: MANUAL SET). We recommend using the automatic calculation (AUTO SET), unless important reasons speak against it. If the alarm for the switching threshold is triggered, the following signals are set: - the current output goes to 4 or 20 mA - Alarm State is ON - the open collector switches
Variable Handling: R
Variable Class: Dynamic | Correction
Variable Size: 4
Variable DataType: Float
Variable Display Format: |en|.0f
Variable Edit Format:
Variable Unit:
Variable Max:
Variable Min:
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
214 | 422D | cmd_rd_meas_parameter |
Variable Write Command List
None