Variable Name: PosVolBase
Variable ID: 0x40AE
Variable Label: Forward Base Condition Volume
Variable Help: Accumulation of base-condition volume (integer portion) in the forward direction. The total is computed using this integer portion (digits to the left of the decimal) with the fractional portion PosVolBaseFrac (digits to the right of the decimal) Note that internally this value rolls over at the units-converted equivalent of an unsigned 64 bit integer (18446744073709551615). However, when read via Modbus, the value rolls from 999,999,999 to 0.
Variable Handling: R
Variable Class: Dynamic
Variable Size: 4
Variable DataType: Integer
Variable Display Format:
Variable Edit Format:
Variable Unit:
Variable Max:
Variable Min:
Variable Read Command List
Command Number | Command ID | Command Name |
---|---|---|
169 | 40AB | ReadFlowTotals |
Variable Write Command List
None