Loading…

Variable Name: diffuser_warn

Variable ID: 0x407F

Variable Label: Diffuser Warn

Variable Help: The diffuser pluggage diagnostic result.

Variable Handling: R/W

Variable Class: Dynamic | Device

Variable Size: 1

Variable DataType: Enum

Variable Enum Value Variable Enum Text
0x0000 None
0x0001 Gas 1 No Detect
0x0002 Gas 2 No Detect
0x0003 Gas 1 Unstable
0x0004 Gas 2 Unstable
0x0005 Process No Detect
0x0006 Purge End Premature
0x0007 Fail Reach Process
0x0008 Diffuser Plugging
0x0009 Constant Shifting

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
174 411C read_plugged_diffuser_params

Variable Write Command List

Command Number Command ID Command Name
177 411E reset_diffuser_warn