Loading…

Variable Name: dvm_fpct

Variable ID: 0x40DC

Variable Label: Pct. A.

Variable Help: The measured percentage of media A in the fluid. Fraction is defined as a part of mixture. Mixtures consisting of two components ( A+ B) which can be measured separately.If the flowmeter is ordered with fraction, e.g °BRIX,the flowmeter is able to calculate the % concentration of sugar in a water (B) + sugar (A) mixture.From factory the table slope 'b' is set to 1.0000. Formula: % concentration = (a / 3600) + bx % concentration = the concentration of media e.g. in °BRIX a = fraction offset in (kg/h) b = is a factor without dimension (table slope) x = is the concentration in % or e.g. °BRIX Example: If you want to change the concentration in % on the flowmeter with +0,5 %, you have to change the table slope 'b' to 1.005. After the change the flowmeter will now show a concentration 0,5 % higher as before.

Variable Handling: R

Variable Class: Correction

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|.1f

Variable Edit Format:

Variable Unit:

Variable Max: 2900

Variable Min: 0

Variable Read Command List

Command Number Command ID Command Name
134 40F4 read_float32

Variable Write Command List

None