Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
aremote_seal_isolator_material | 400B | RS isoltr matl | Remote Seal Isolator Material - Defines the material of the remote seal wetted diaphragm. | R | Enum | 2048 |
amodule_isolator_material | 400C | Isoltr matl | Module Isolator Material - Indicates the material of the sensor diaphragm. | R | Enum | 2048 |
aremote_seal_type | 400D | RS type | Remote Seal Type - Defines the type of Remote seal. | R | Enum | 2048 |
remote_seal_fill_fluid | 400E | RS fill fluid | Remote Seal Fill Fluid - Defines the remote seal filling liquid. | R | Enum | 2048 |
anumber_of_remote_seals | 400F | Num remote seal | Number of Remote Seals - Physical quantity of the seals for the remote seal that is installed. | R | Enum | 2048 |
amodule_fill_fluid | 4010 | Fill fluid | Sensor Fill Fluid - Fluid material in the module. | R | Enum | 2048 |
module_range_code | 4011 | Module rnge | Module range - This is the range for the sensor. | R | Enum | 2048 |
acalibration_type | 4012 | Calib typ | Calibration Type - Indicates if std. or specific on operating pressure or temperature or both. | R | Enum | 2048 |
procedure_type | 4013 | Procedure Type | Procedure Type - It is the type of any special procedure required for the manufacture of the sensor, e.g. degreasing. | R | Enum | 2048 |
local_keys_mode | 4014 | Local keys mode | Local keys mode control - Disables the Zero and Span Push buttons. | R/W | Enum | 2048 |
Name | ID | Label | Description | Type | Access | Class |