Loading…
Loading…
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
wOutputMode | 4016 | Output Mode | Determines the operation of the pulse outputs. | 读/写 | 整型 | 1024 |
wCurrentMode | 401A | Current mode | Determines the electrical characteristic of the analog output. | 读/写 | 枚举 | 2048 |
wStandbyMode | 401B | Standby Mode | Reduces power consumption during metering pauses by turnin off meter coil excitation current. | 读/写 | 枚举 | 2048 |
wParMode | 400F | Parameter Mode | Security function for the parameters which allows the parameters to be protected agains unauthorized changes. | 读/写 | 枚举 | 2048 |
rQmax | 4036 | Qmax | Determines the scaling of the analog output, 100% Qmax = 20 mA. | 读/写 | 浮点 | 8 |
rIMP1Pulses | 400A | pv1 | Determines the number of pulses per volume unit seen at output IMP1. Value pv1 is used when several channels are available. | 读/写 | 浮点 | 512 |
rIMP2Pulses | 4012 | pv2 | Determines the number of pulses per volume unit seen at output IMP2. Only inflow is possible at Output-mode 1.5. | 读/写 | 浮点 | 512 |
wIMP1OnTime | 401C | tp1 | Determines the maximum ON time duration for the pulse output IMP1. | 读/写 | 整型 | 512 |
wIMP2OnTime | 401D | tp2 | Determines the maximum ON time duration for the pulse output IMP2. | 读/写 | 整型 | 512 |
wIMP3OnTime | 401E | Meter Out Damp (tp3) | Damping of optional analog output 0/4-20 mA. | 读/写 | 整型 | 512 |