Loading…
Loading…
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
SV1_CalVanDusen_C | 407F | Coefficient C | Coefficient C for Callendar van-Dusen linearisation. | 读/写 | 浮点 | 2048 |
SV1_CalVanDusen_R0 | 4080 | R0 | R0 for Callendar van-Dusen linearisation. | 读/写 | 浮点 | 2048 |
Max_Indicator_0 | 403B | Max value S1 | Shows the maximum process value of sensor 1. The value can be written to reset the indicator. | 读/写 | 浮点 | 2050 |
Min_Indicator_0 | 403C | Min value S1 | Shows the minimum process value of sensor 1. The value can be written to reset the indicator. | 读/写 | 浮点 | 2050 |
Value_0 | 401C | Value Sensor 1 | This parameter shows the measuring value of sensor 1. | 读 | 浮点 | 2050 |
Status_0 | 4038 | Status sensor 1 | Status sensor 1 - The status of sensor 1 is shown. | 读 | 无符号 | 2051 |
Sensortype_1 | 4009 | Sensor 2 type | Allocation of sensor 2 sensor type using a selection list. | 读/写 | 枚举 | 2048 |
Sensor_Connection_1 | 400A | Sensor 2 connect. | Allocation of connection mode (2-/3-wire) on resistance thermometers and resistance transmitters. | 读/写 | 枚举 | 2048 |
RJ_Mode_1 | 4027 | Cold junction S2 | For TC input only. Selection of cold junction position. Internal: The temperature measured by the internal cold junction of the transmitter is used as compensation. External: The preset temperature is used for compensation. | 读/写 | 枚举 | 2048 |
RJ_Fixed_Value_1 | 4028 | External temp. S2 | Fixed preset temperature. This is the temperature used for compensation when measuring using thermocouples. | 读/写 | 浮点 | 2048 |