Loading…
Name ID Label Description Type Access Class
percentRange 00E9 % Meas Range Percentuale di campo - Variabile che traccia la rappresentazione del valore digitale rispetto al campo definito dal valore di campo inferiore e dal valore di campo superiore, per le modalità operative normali. Le unità di questa variabile sono sempre in percentuale. R Float 34
transfer_function 1F84 Transfer Function Transfer Function Here you can specify how the current output should behave in case of a change in level: LINEAR A continuous 4-20 mA signal is output which is proportional to the count rate. DISCRETE SWITCH Depending on the set switching threshold (alarm threshold for the level) a current of 4 mA or 20 mA is output. Values between 4 and 20 mA will not be output. R/W Enum 32
upperRange_value 00EA Upper Range Value Valore di campo superiore - Definisce il punto finale operativo da cui deriva il valore analogico e il punto 100% del campo percentuale. Inoltre, il valore di campo superiore definisce un punto finale operativo da cui derivano gli allarmi associati al valore analogico e gli allarmi associati alla rappresentazione del valore digitale. R Float 32
lowerRange_value 00EB Lower Range Value Valore di campo inferiore - Definisce il punto finale operativo da cui si ricava il valore analogico e il punto 0% del campo percentuale. Inoltre, il valore di campo inferiore definisce un punto finale operativo da cui derivano gli allarmi associati al valore analogico e gli allarmi associati alla rappresentazione del valore digitale. R Float 32
response_code 0096 Response code Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. R Enum 129
comm_status 0098 Communication status Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. R BitEnum 131
request_preambles 009B Num Req Preams Number of Request Preambles- Number of Preambles required from the Host request by the Field Device R Unsigned 128
universal_revision 009C Universal rev Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to R Unsigned 128
transmitter_revision 009D Field Dev Rev Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to R Unsigned 128
software_revision 009E Software Rev Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device R Unsigned 2048
Name ID Label Description Type Access Class