Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
var_ds_ascLicenseKey5 | 400A | License Key Part5 | R/W | ASCII | 2048 | |
var_dd_dtActiveDate | 400B | Date | Date Enter here the current date. The date is necessary for the proper work of the decay compensation and also for the error log and modification log, to know at which day the error or a parameter modification happened. | R/W | HartDate | 10 |
var_dd_ascActiveTime | 400C | Time | Time Enter here the current time. The time is necessary for the error log and modification log, to know at which time the error or a parameter modification happened. | R/W | ASCII | 10 |
var_dd_eOperatingMode | 400D | Operating Mode | Operating Mode RUN The measurement is in the normal measurement mode. WARNING A warning message has appeared. The error code is indicated in "Sensor Settings". ERROR An error is indicated. The error code is displayed in "Sensor Settings". SHUTDOWN A serious error is indicated. The error code is displayed in "Sensor Settings". HOLD The measurement is in the hold state, which means that the measured value and the current output signal is frozen. This status can occur under the following conditions: - the plateau recording is running - interference radiation was detected - the digital input is on Hold TEST A test value is enabled. | R | Enum | 2051 |
var_dd_eSafetyMode | 400E | Safety Mode | Safety Mode Indicates whether the safety mode is enabled: ON Safety mode is enabled. OFF Safety mode is disabled. | R/W | Enum | 2050 |
var_ls_eSafetyModeOff | 400F | R/W | Enum | 4096 | ||
var_ls_eSafetyModeOn | 4010 | R/W | Enum | 4096 | ||
var_ds_eErrorHandling | 4011 | Error Handling | Error Handling Here you can set a different weighting of errors and error handling: SENSITIVE All faults cause the current output to report a Fault current. To also get warning messages, you must also evaluate the messages via the HART® signal or the digital output. NORMAL Only fatal errors are reported as a fault current. Thus, the measured via the current signal will fail only if the measurement can no longer be used. To also get minor error and warning messages, you must also evaluate the messages via the HART® signal or the digital output. | R/W | Enum | 8 |
var_ds_eResetDevice | 4012 | Reset Device | R/W | Enum | 8 | |
var_ds_uiChangeLogIndex | 4013 | Mod Log Index | Mod Log Index Active Index of modification log entry | R/W | Unsigned | 2048 |
Name | ID | Label | Description | Type | Access | Class |