Loading…
Name ID Label Description Type Access Class
varPassword 406F Set Password Password required to unlock a HART password protected instrument. W Password 0
varUnlockPassword 4025 Password to Unlock Password required to unlock HART password protected instrument. W Password 4
varUnlockState 4023 Password Lock Current state of password lock. R Enum 4
varAlm1OnThreshold 403B On Threshold Alarm activiation level R/W Float 0
varAlm1OffThreshold 403C Off Threshold Alarm de-activiation level R/W Float 0
varAlm1OnDelay 403D On Delay Delay (in seconds) to alarm activation once on-threshold crossed. R/W Unsigned 0
varAlm1OffDelay 403E Off Delay Delay (in seconds) to alarm de-activation once off-threshold crossed. R/W Unsigned 0
varAlm1Latching 403F Latching Specifies if alarm 1 is latched once alarm condition clears. R/W Enum 0
varAlm1Relay 4040 Relay Specifies default state of relay. R/W Enum 0
varAlm1Direction 4041 Direction Specifies whether alarm is rising or falling. R/W Enum 0
Name ID Label Description Type Access Class