0 |
ABB |
1 |
600T |
2 |
EEPROM 1 error |
3 |
EEPROM 2 error |
4 |
Stat Pres ool |
5 |
Sens Temp ool |
6 |
Elec Temp ool |
7 |
Sensor failed |
8 |
ASIC Counter ool |
9 |
Checksum error |
10 |
Stat Pres oopl |
11 |
Sens Temp oopl |
12 |
Elec Temp oopl |
13 |
Field Device Primary Variable Unit - Engineering unit that the Digital Value, Upper Range Value and Lower Range value will be displayed with. |
14 |
inH2O @20DegC |
15 |
inHg @0DegC |
16 |
feet H2O @20DegC |
17 |
mmH2O @20DegC |
18 |
mmHg @0DegC |
19 |
torr @0DegC |
20 |
Up-Down Scale mode - Defines the setting of the current output when fatal errors are detected. |
21 |
Up-Down Scale mode |
22 |
Transfer Function - Defines the transformation function that will be applied between the Field Device Variable and the respective assigned Analog Output. The transfer function does not affect the Digital Value. |
23 |
5th Order polyn |
24 |
Meter Installation - Defines whether there is a meter installed or not and, if integral, what information the meter will display. |
25 |
Analog - 4-20mA |
26 |
Digital - 4-20mA |
27 |
Integral digital |
28 |
Push Buttons - Indicates whether the instrument is fitted with Zero and/or Span calibration buttons. |
29 |
Push Buttons |
30 |
No Push Buttons |
31 |
Zero Pushbutton only |
32 |
Zero & Span Pushbut. |
33 |
Flange Type - Hardware, adjacent to the sensor, that physically connects the process to the sensor. |
34 |
1/2in NPT-F |
35 |
DIN |
36 |
Conventl. + insert |
37 |
Flange Material - Indicates the material of the flange. |
38 |
17-4-PH |
39 |
316L + PTFE insert |
40 |
Oring Material - Indicates the construction material of a seal that exists between the module and the flange. |
41 |
TFE Glass filled |
42 |
Drain Vent Material - Indicates the material of the vents. |
43 |
AISI 303 SS |
44 |
AISI 316L SS NACE |
45 |
Remote Seal Isolator Material - Defines the material of the remote seal wetted diaphragm. |
46 |
Hastelloy C276 |
47 |
AISI 316L TFE Coated |
48 |
Nickel |
49 |
Zirconium |
50 |
Silver |
51 |
Module Isolator Material - Indicates the material of the sensor diaphragm. |
52 |
Remote Seal Type - Defines the type of Remote seal. |
53 |
Threaded |
54 |
Chemical Tee |
55 |
Button |
56 |
Tri Clamp |
57 |
Threaded food |
58 |
Union Connection |
59 |
Remote Seal Fill Fluid - Defines the remote seal filling liquid. |
60 |
Santotherm |
61 |
Silicon oil food |
62 |
Neobee |
63 |
Dowtherm |
64 |
Ethyl benzene |
65 |
Ethyl alcohol |
66 |
Propylene glycol/Water |
67 |
Dibutyl penthalate |
68 |
Siltherm 800 |
69 |
Number of Remote Seals - Physical quantity of the seals for the remote seal that is installed. |
70 |
Sensor Fill Fluid - Fluid material in the module. |
71 |
Module range - This is the range for the sensor. |
72 |
2.5 kpa |
73 |
5 kpa |
74 |
7.5 kpa |
75 |
10 kpa |
76 |
12.5 kpa |
77 |
15 kpa |
78 |
25 kpa |
79 |
40 kpa |
80 |
50 kpa |
81 |
60 kpa |
82 |
80 kpa |
83 |
120 kpa |
84 |
140 kpa |
85 |
160 kpa |
86 |
200 kpa |
87 |
250 kpa |
88 |
400 kpa |
89 |
600 kpa |
90 |
1200 kpa |
91 |
1600 kpa |
92 |
2400 kpa |
93 |
3200 kpa |
94 |
4200 kpa |
95 |
4800 kpa |
96 |
6000 kpa |
97 |
25 mbar |
98 |
50 mbar |
99 |
75 mbar |
100 |
100 mbar |
101 |
125 mbar |
102 |
150 mbar |
103 |
250 mbar |
104 |
400 mbar |
105 |
500 mbar |
106 |
600 mbar |
107 |
800 mbar |
108 |
1200 mbar |
109 |
1400 mbar |
110 |
1600 mbar |
111 |
2000 mbar |
112 |
2500 mbar |
113 |
4000 mbar |
114 |
6000 mbar |
115 |
12000 mbar |
116 |
16000 mbar |
117 |
24000 mbar |
118 |
32000 mbar |
119 |
42000 mbar |
120 |
48000 mbar |
121 |
60000 mbar |
122 |
10 mpa |
123 |
12 mpa |
124 |
16 mpa |
125 |
25 mpa |
126 |
32 mpa |
127 |
40 mpa |
128 |
60 mpa |
129 |
80 mpa |
130 |
100 mpa |
131 |
10 inH2O |
132 |
20 inH2O |
133 |
30 inH2O |
134 |
40 inH2O |
135 |
50 inH2O |
136 |
60 inH2O |
137 |
100 inH2O |
138 |
160 inH2O |
139 |
200 inH2O |
140 |
240 inH2O |
141 |
320 inH2O |
142 |
480 inH2O |
143 |
560 inH2O |
144 |
640 inH2O |
145 |
800 inH2O |
146 |
46 mmHg |
147 |
37 mmHg |
148 |
56 mmHg |
149 |
75 mmHg |
150 |
93 mmHg |
151 |
112 mmHg |
152 |
187 mmHg |
153 |
300 mmHg |
154 |
375 mmHg |
155 |
450 mmHg |
156 |
600 mmHg |
157 |
900 mmHg |
158 |
1050 mmHg |
159 |
1200 mmHg |
160 |
1500 mmHg |
161 |
58 psia |
162 |
87 psia |
163 |
174 psia |
164 |
232 psia |
165 |
348 psia |
166 |
464 psia |
167 |
609 psia |
168 |
696 psia |
169 |
870 psia |
170 |
58 psig |
171 |
87 psig |
172 |
174 psig |
173 |
232 psig |
174 |
348 psig |
175 |
464 psig |
176 |
609 psig |
177 |
696 psig |
178 |
870 psig |
179 |
1450 psi |
180 |
1740 psi |
181 |
2320 psi |
182 |
3625 psi |
183 |
4641 psi |
184 |
5801 psi |
185 |
8702 psi |
186 |
11603 psi |
187 |
14503 psi |
188 |
Calibration Type - Indicates if std. or specific on operating pressure or temperature or both. |
189 |
Procedure Type - It is the type of any special procedure required for the manufacture of the sensor, e.g. degreasing. |
190 |
Procedure Type |
191 |
Oxygen Cleaning |
192 |
Chlorine Cleaning |
193 |
Hydrogen Preparation |
194 |
Special Degreasing |
195 |
Local keys mode control - Disables the Zero and Span Push buttons. |
196 |
Local keys mode |
197 |
LCD display mode control - Selects the variables shown on the integral display. |
198 |
LCD display mode |
199 |
Process variable |
200 |
PV & % of range |
201 |
PV & oput current |
202 |
% of range |
203 |
Root transfer function mode - selects behaviour of square root output at input values from 0 - 4 %. |
204 |
Root transfer mode |
205 |
Linear 20 % oput |
206 |
Lin 1:1 20 % oput |
207 |
Field Device Primary Variable Value - Represents the input pressure. |
208 |
.3f |
209 |
.2f |
210 |
Sensor Limit Units and Minimum Span Units - Engineering units that the Upper Sensor Limit, Lower Sensor Limit and Minimum Span will be displayed with. |
211 |
Sensor Limits Units |
212 |
Module Type - Defines the Module type of the field instrument. |
213 |
High Static Pressure |
214 |
Special Transfer Function. |
215 |
Special Transfer Function |
216 |
Lower Sensor Trim Point - Applied process pressure at which the last lower sensor trim was performed. Pressure Sensor - Pressure hardware that measures pressure with respect to some reference pressure. |
217 |
Upper Sensor Trim Point - Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor - Pressure hardware that measures pressure with respect to some reference pressure. |
218 |
Sensor trim units - It is the unit of the sensor trim points. |
219 |
Sensor trim units |
220 |
Maximum Working Pressure - Indicates the maximum pressure to which the transmitter can be submitted without causing danger and damage. |
221 |
Maximum Working Pressure Units - The units of the Maximum working pressure. |
222 |
Maximum sensor Pressure - Indicates the maximum temperature to which the sensor or the electronic can be submitted without causing danger and damage. |
223 |
Max sens temp |
224 |
Max sens temp units |
225 |
Maximum sensor temperature units - The units of the Maximum sensor or electronic temperature units. |
226 |
Minimum sensor Temperature - Indicates the minimum temperature to which the sensor or the electronic can be submitted without causing danger and damage. |
227 |
Min sens temp |
228 |
Min sens temp units |
229 |
Minimum sensor temperature units - The units of the Minimum sensor or electronic temperature units. |
230 |
A5 coefficient - A5 coefficient for polynomial function. |
231 |
A5 |
232 |
1.6g |
233 |
A4 coefficient - A4 coefficient for polynomial function. |
234 |
A4 |
235 |
A3 coefficient - A3 coefficient for polynomial function. |
236 |
A3 |
237 |
A2 coefficient - A2 coefficient for polynomial function. |
238 |
A2 |
239 |
A1 coefficient - A1 coefficient for polynomial function. |
240 |
A1 |
241 |
A0 coefficient - A0 coefficient for polynomial function. |
242 |
A0 |
243 |
Analog Output value - Indicates the current output of the field instrument. |
244 |
Analog Output |
245 |
Percent of Range - Digital value that is proportional to the range defined by the Lower Range Value and the Upper Range Value. The units of this variable is always in percent. |
246 |
% |
247 |
Upper Sensor Limit - Value that defines the absolute upper endpoint (largest magnitude) for the digital value. Pressure - Pressure of the process measured with respect to some reference pressure. |
248 |
.1f |
249 |
Lower Sensor Limit - Value that defines the absolute lower endpoint (smallest magnitude) for the digital value. Pressure - Pressure of the process measured with respect to some reference pressure. |
250 |
Upper Range - Defines the operational endpoint from which the Analog Value and the Percent of Range are derived. In addition, the range values define the points at which the 'analog output saturated' warning is set. |
251 |
Lower Range - Defines the operational endpoint from which the Analog Value and the Percent of Range are derived. In addition, the range values define the points at which the 'analog output saturated' warning is set. |
252 |
Damping Value - Damping time constant applied to both the Digital Value and Analog Value of the respective output. The Units of this variable are always in seconds. |
253 |
2.2f |
254 |
5.2f |
255 |
Tertiary variable Static Pressure Value. |
256 |
Static Pres |
257 |
Tertiary variable Static Pressure Units. |
258 |
Sta pres unit |
259 |
Static Pressure trim point - The pressure at which static trim is to take place. |
260 |
Stat Pres trim pt |
261 |
Static Pressure Trim Unit - Units of the static pressure trim point. |
262 |
Stat Pres trim unit |
263 |
MPa |
264 |
Secondary variable Sensor Temperature Value - The displayed temperature is not the process temperature, it is the temperature in the sensor's core. |
265 |
Snsr temp |
266 |
Secondary variable Sensor Temperature Unit. |
267 |
Snsr temp unit |
268 |
Fourth Variable - Temperature of the electronics. |
269 |
Elec temp |
270 |
Fourth Variable Electronic Temperature Unit. |
271 |
Product Code - Specifies the transmitter's code number. |
272 |
Product code |
273 |
Separator &/or Services - Indicates the code of remote seal or code for special services or calibration. |
274 |
Sepratr&/Service |
275 |
Manifold or Orifice - Indicates the code of manifold or integral orifice. |
276 |
Manf or orifice |
277 |
Minimum Span value - Indicates the minimum allowable value for the span. The span is the algebraic difference between the Upper and Lower Range Value. |
278 |
Min span |
279 |
Sensor Serial Number - Indicates the sensor module serial number. |
280 |
7d |
281 |
Up Down Scale Mode |
282 |
This is the array for the dynamic variables |
283 |
Field Device Dynamic variables array |
284 |
|
285 |
Excess Correction Attempted |
286 |
Configure |
287 |
Zero/Span cal |
288 |
Status |
289 |
Pres sensor trim |
290 |
Sensor trim points |
291 |
Sensor |
292 |
Pres sensor |
293 |
Pres sensor info |
294 |
Temp sensor |
295 |
Stat sensor |
296 |
Pres input scaling |
297 |
Display Limits |
298 |
Product codes |
299 |
Material Info |
300 |
Revision #'s |
301 |
Misc Info |
302 |
write_variables |
303 |
Offline |
304 |
Back to normal |
305 |
Back to normal with msg |
306 |
Factory trim |
307 |
Factory trim method - The factory trimming is a reset to the values used in the factory for the trimming operation and can be usually done without the need of external equipment. |
308 |
Full trim method - The full trimming allows the performance of high or low trim. |
309 |
Full trim |
310 |
Static trim method - The static trimming allows a single point trim of Static Pressure |
311 |
Static trim |
312 |
Rerange 4-20mA |
313 |
Perform a device rerange to 4 - 20ma by applying source pressure input. |
314 |
Put coef0 into range 0-100 |
315 |
Put coef2 into range 0-100 |
316 |
Put coef3 into range 0-100 |
317 |
Put coef4 into range 0-100 |
318 |
Put coef5 into range 0-100 |
319 |
Put coef0 into range 0-1 |
320 |
Put coef2 into range 0-1 |
321 |
Put coef3 into range 0-1 |
322 |
Put coef4 into range 0-1 |
323 |
Put coef5 into range 0-1 |
324 |
Danger for max working pressure |
325 |
Loop in manual |
326 |
Before polling |
327 |
Commands the DPK pressure electronics to perform a selftest. |
328 |
Polyn. coeffs |
329 |
FMU860 |
330 |
DT |
331 |
DVC |
332 |
FCX |
333 |
AS800 |
334 |
340T |
335 |
340C |
336 |
344 |
337 |
Siemens Micro K |
338 |
SITRANS L |
339 |
SIPAN PH |
340 |
SITRANS P |
341 |
75SMT |
342 |
UNIDELTA |
343 |
8320 |
344 |
SX5100 |
345 |
TSV175 |
346 |
DMU |
347 |
3780 |
348 |
BM70 |
349 |
8u |
350 |
low |
351 |
high |
352 |
Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. |
353 |
Send warning |
354 |
Send Warning- Yields a units code notice to the User. |
355 |
Variables which use this as the units code will be in the previous units until this value is sent to the device. |
356 |
Note: Loop may be returned to automatic control when SEND is done |
357 |
If transfer function changed chech square root mode & poly coeffs. |
358 |
Trim will be set as at factory |
359 |
Applied values read:
PV: %{1}
Units: %{0} |
360 |
Applied zero reads:
PV: %{1}
Units: %{0} |
361 |
Last Input val used:
Units: %{0}
Hival: %{2}
Loval: %{1} |
362 |
Select choice: |
363 |
High Trim;Low Trim;Display limits;Exit |
364 |
Apply a Hival Pres. Higher than Loval |
365 |
Pressure stabilizing. PLEASE WAIT... |
366 |
Units: %{0}
Pres. applied: %{1} |
367 |
Enter applied Hival: |
368 |
Aborting procedure due to last error |
369 |
Apply a Loval Pres. Lower than Hival |
370 |
Enter applied Loval: |
371 |
SENSOR LIMITS:
Units:%{0}
USL: %{2}
LSL: %{1} |
372 |
Static value read
stat value: %{0}
units: %{1} |
373 |
Modify;Ready |
374 |
Enter static value: |
375 |
Now Apply input pressure
(URV is %{0})
(LRV is %{1}) |
376 |
Current process value: %{0} %{1} |
377 |
Read new value;Set as 4mA value;Set as 20mA value;Exit |
378 |
DANGER: Change of this value affects plant and personnel safety. MUST be done by qualified personnel only. |
379 |
WARN: TX with polling address different from 0 cannot be part of a control loop. |
380 |
Executing selftest. PLEASE WAIT... |
381 |
Self test terminated |