0 |
QUANTIM |
1 |
Alarm Status Zero |
2 |
Mass Flow Alarm |
3 |
Density Alarm |
4 |
Temperature Alarm |
5 |
Slug Flow Alarm |
6 |
Volumetric Flow Alarm |
7 |
Undefined Alarm |
8 |
Alarm Status One |
9 |
Diagnostic Alarm |
10 |
Database Initalization Alarm |
11 |
Power Fail Alarm |
12 |
Internal Temp Alarm |
13 |
Reserved Alarm (RTD) |
14 |
Reserved Alarm (Pulse Out Config) |
15 |
Reserved Alarm (Pulse Out Overrun) |
16 |
Diagnostic Status Two |
17 |
Undefined Diagnostic Test |
18 |
Calibration |
19 |
Analog to Digital Converter |
20 |
Reserved (Pic Failure) |
21 |
Digital Signal Processor Test |
22 |
EEProm Test |
23 |
Flash Memory Test |
24 |
Ramdom Access Memory Test |
25 |
Warning Status Three |
26 |
Mass Flow Warning |
27 |
Density Warning |
28 |
Temperature Warning |
29 |
Slug Flow Warning |
30 |
Volumetric Flow Warning |
31 |
Undefined Warning |
32 |
Warning Status Four |
33 |
Diagnostic Warning |
34 |
Database Initalization Warning |
35 |
Power Fail Warning |
36 |
Internal Temp Warning |
37 |
Reserved Warning (RTD) |
38 |
Reserved Warning (Pulse Out Config) |
39 |
Reserved Warning (Pulse Out Overrun) |
40 |
Place Holder. |
41 |
One byte variable used as a place holder for COMMAND 144. |
42 |
3d |
43 |
Firmware Rev |
44 |
Meaningful revision information of the software currently residing in flash. |
45 |
Model # |
46 |
The Brooks Instrument model number of the Field Device. |
47 |
Serial # |
48 |
The Brooks Instrument unique serial number assigned to the Field Device. |
49 |
Mass Flow |
50 |
The flow rate of the controlled substance has exceeded device limits. |
51 |
Normal |
52 |
Warning |
53 |
Alarm |
54 |
Density |
55 |
The density of the controlled substance has excceded maximum limits. |
56 |
Temperature |
57 |
The temperature of the controlled substance has exceeded maximum limits. |
58 |
Slug Flow |
59 |
Volumetric Flow |
60 |
Undefined |
61 |
Device issued an Alarm or Warning that is undefined. |
62 |
Diagnostic |
63 |
Device Diagnostics detected a problem, see Diagnostic Status for more information. |
64 |
Data Base Inititalization |
65 |
The field device's interanl database has been initialized to default values. |
66 |
Power Fail |
67 |
A internal power supply failure has occured. |
68 |
Internal Temperature |
69 |
The internal temperature of the device has exceededd maximum limits. |
70 |
Reserved |
71 |
Field Device Unsupported Alarm/Warning. |
72 |
Resistive Temperature Device |
73 |
Resistive Temperature Device performance degraded. |
74 |
Pulse Out Config |
75 |
The pulse output configuration parameters are in error or confilict. |
76 |
Pulse Out Overrun |
77 |
The process flow rate has excceded the configured pulse output parameters. |
78 |
Alarm Selected |
79 |
Value used to select the next alarm to configure. |
80 |
Mass |
81 |
Dens |
82 |
Volu |
83 |
Temp |
84 |
Temerature Alarm |
85 |
Slug |
86 |
Diag |
87 |
Diagnostic Fail Alarm |
88 |
Alarm Code |
89 |
Sets the number of LED flashes used to represent the activation of the current alarm. |
90 |
Alarm Severity |
91 |
Sets the level at which the alarm is triggered. |
92 |
Off |
93 |
Contact Enable |
94 |
Assigns the Field Devices physical alarm contacts to the current alarm. |
95 |
No |
96 |
Yes |
97 |
Alarm Latch Enable |
98 |
Enables latching of the alarm. This requires an active alarm to be reset via user intervention. |
99 |
Low Limit |
100 |
The value of the signal under test that is less than or equal to the value that will trigger an alarm. |
101 |
6.2f |
102 |
High Limit |
103 |
The value of the signal under test that is greater than or equal to the value that will trigger an alarm. |
104 |
Alarm Delay |
105 |
A delay that inhibits the setting of an alarm until after the specified elapsed time. |
106 |
Undefined Status Bit |
107 |
Status bit undefined for this device. |
108 |
Asserted |
109 |
RTD Failure |
110 |
Resistive Temperature Device has failed. |
111 |
Drive Output Saturated |
112 |
Tube drive output saturated. |
113 |
Pickoff Inputs Saturated |
114 |
Tube sensor pickoff inputs saturated. |
115 |
Sensor NOT Ready |
116 |
The sensor's Digital Signal Processor is NOT ready. |
117 |
Delta T Overflow |
118 |
Tube sensors Delta T value arithmatic overflow. |
119 |
Frequency Error |
120 |
Sensor Tube excitation frequnecy error. |
121 |
DSP EEProm Fail |
122 |
Digital Signal Processor EEProm Fail. |
123 |
Valid but undefined Field Device diagnostic test. |
124 |
Failed |
125 |
Cal Diag Test |
126 |
Field Device Calibration parameters comformance/diagnostic test. |
127 |
ADC Diag Test |
128 |
Field Device Anolog to Digital Converter diagnostic test. |
129 |
PIC Fail |
130 |
Field Device PIC proccessor Failure . |
131 |
Reserved Diag Test |
132 |
Field Device Unsupported Diagnostic Test. |
133 |
Sensor Diag Test |
134 |
Field Device Digital Signal Processor diagnostic test. |
135 |
EEProm Diag Test |
136 |
Field Device EEProm diagnostic memory test. |
137 |
Flash Mem Diag Test |
138 |
Field Device Flash Memory diagnostic test. |
139 |
RAM Diag Test |
140 |
Field Device Random Access Memory diagnostic test. |
141 |
Number of Active Alarms |
142 |
Number of alarms raised by the device. |
143 |
Number of Active Warnings |
144 |
Number of warnings raised by the device. |
145 |
Number of Failed Diagnostics |
146 |
Number of device diagnostic routines that failed. |
147 |
Number of Asserted DSP Sensor Status Bits |
148 |
Number of Digital Signal Processor Sensor status bits asserted. |
149 |
DSP Sensor Status Bytes |
150 |
Current status of the Digital Signal Processor represented in a two byte bit field. |
151 |
5d |
152 |
DSP Sensor F/W Rev |
153 |
Current DSP firmware revision number, raw format. |
154 |
Sensor F/W Rev |
155 |
Current sensor firmware revision number, converted format. |
156 |
S/D |
157 |
Collection of drive and sensor variables. |
158 |
L Pic |
159 |
R Pic |
160 |
TubeCy |
161 |
DeltaT |
162 |
TDGain |
163 |
ValDrv |
164 |
Val State |
165 |
Left Pickoff Ampl |
166 |
Value calculated by the Digital Signal Processor, representing 1 milliVolt per bit for the left side tube pickoff sensor. |
167 |
mV |
168 |
Right Pickoff Ampl |
169 |
Value calculated by the Digital Signal Processor, representing 1 milliVolt per bit for the right side tube pickoff sensor. |
170 |
Tube Drive Gain, Relative |
171 |
0.1(DAC count)/(MDAC bit). |
172 |
Cnts |
173 |
3.1f |
174 |
Tube Osc Period |
175 |
The Period of the Sensor Tube oscillations expressed in milliseconds. |
176 |
msec |
177 |
DeltaT represents the phase difference between the left and right tube sensors, expressed in milliseconds. |
178 |
usec |
179 |
Valve Drive |
180 |
Valve drive expressed in percent of full scale. |
181 |
% |
182 |
4.1f |
183 |
State |
184 |
State of the valve drive control loop. |
185 |
Control |
186 |
Valve under standard control. |
187 |
Closed |
188 |
Valve locked closed. |
189 |
Open |
190 |
Valve locked open. |
191 |
Fixed |
192 |
Valve driven via a fixed voltage. |
193 |
Mass Flow Analog Alarm Code |
194 |
Sets the number of LED flashes used to represent the activation of a Mass Flow alarm. |
195 |
Mass Flow Alarm Behavior |
196 |
Action taken by the Field Device and applied to flow when a Mass Flow alarm condition occurs. |
197 |
Track |
198 |
Hold |
199 |
Upscale |
200 |
Downscale |
201 |
Mass Flow A/O Value |
202 |
Digital representation of the analog output signal (in milliamps) for Mass Flow. |
203 |
mA |
204 |
6.3f |
205 |
Mass Flow Digital Damping Value |
206 |
5.1f |
207 |
Mass Flow Minimum Span |
208 |
The minimum allowable delta between the Mass Flow Range Upper and Lower values. |
209 |
7.3f |
210 |
Mass Flow Sensor Lower Limit |
211 |
The lower limit of the Mass Flow sensor's operational range. |
212 |
Mass Flow Sensor Upper Limit |
213 |
The upper limit of the Mass Flow sensor's operational range. |
214 |
Mass Flow Units |
215 |
Mass Flow Value |
216 |
The digital value representing Mass Flow. |
217 |
Mass Flow Percent Range |
218 |
Current percentage of the full scale value for Mass Flow analog output. |
219 |
Mass Flow Range Lower Value |
220 |
The lower limit of the analog Mass Flow signal. |
221 |
Mass Flow Range Upper Value |
222 |
The upper limit of the analog Mass Flow signal. |
223 |
Mass Flow Sensor Serial Number |
224 |
Unique serial number for this Field Devices Mass Flow sensor. |
225 |
Mass Flow Transfer Function |
226 |
. |
227 |
9d |
228 |
Density A/O Alarm Code |
229 |
Sets the number of LED flashes used to represent the activation of a Density alarm. |
230 |
Density Alarm Behavior |
231 |
Action taken by the Field Device and applied to flow when a Density alarm condition occurs. |
232 |
Density A/O Value |
233 |
Digital representation of the analog output signal (milliamps) for Density. |
234 |
Density Digital Damping Value |
235 |
Density Minimum Span |
236 |
The minimum allowable delta between the Density Range Upper and Lower values. |
237 |
Density Sensor Lower Limit |
238 |
The lower limit of the analog Density signal. |
239 |
Density Sensor Upper Limit |
240 |
The upper limit of the analog Density signal. |
241 |
Density Units |
242 |
Density Value |
243 |
The digital value representing Density. |
244 |
5.3f |
245 |
Density Percent Range |
246 |
Current percentage of the full scale value for Density analog output. |
247 |
Density Range Lower Value |
248 |
The lower limit of the analog Density signal |
249 |
7.5f |
250 |
Density Range Upper Value |
251 |
The upper limit of the analog Density signal |
252 |
Density Sensor Serial # |
253 |
Unique serial number for this Field Devices Density sensor. |
254 |
Density Xfer Func |
255 |
Volume Flow A/O Alarm Code |
256 |
Sets the number of LED flashes used to represent the activation of a Volumetric Flow alarm. |
257 |
Volumetric Flow Alarm Behavior |
258 |
Action taken by the Field Device and applied to flow when a Volumetric Flow alarm condition occurs. |
259 |
Volume Flow A/O Value |
260 |
The analog output signal in milliamps for Volmetric Flow. |
261 |
Volume Flow Digital Damping Value |
262 |
Volume Flow Minimum Span |
263 |
The minimum allowable delta between the Volumetric Flow Range Upper and Lower values. |
264 |
Volume Flow Sensor Lower Limit |
265 |
The lower limit of the Volumetric Flow sensor's operational range. |
266 |
Volume Flow Sensor Upper Limit |
267 |
The upper limit of the Volumetric Flow sensor's operational range. |
268 |
Volumetric Flow Units |
269 |
cc/hr |
270 |
Cubic Centimeters per Hour |
271 |
cc/min |
272 |
Cubic Centimeters per Minute |
273 |
ml/hr |
274 |
Milliliter per Hour |
275 |
ml/min |
276 |
Milliliter per Minute |
277 |
The digital value representing Volumetric Flow. |
278 |
Volumetric Flow Percent Range |
279 |
Current percentage of the full scale value for Volumetric Flow analog output. |
280 |
Volume Flow Range Lower Value |
281 |
The lower limit of the analog Volumetric Flow signal |
282 |
Volume Flow Range Upper Value |
283 |
The upper limit of the analog Volumetric Flow signal. |
284 |
Volume Flow Sensor Serial # |
285 |
Unique serial number for this Field Devices Volumetric Flow sensor. |
286 |
Volume Flow Xfer Funct |
287 |
Temp A/O Alarm Code |
288 |
Sets the number of LED flashes used to represent the activation of a Temperatrue alarm. |
289 |
Temperature Alarm Behavior |
290 |
Action taken by the Field Device and applied to flow when a Temperature alarm condition occurs. |
291 |
Temp A/O Value |
292 |
Digital representation of the analog output signal (milliamps) for Temerature. |
293 |
Temp Digital Damping Value |
294 |
Temp Minimum Span |
295 |
The minimum allowable delta between the Temperatrue Range Upper and Lower values. |
296 |
Temp Lower Sensor Limit |
297 |
The lower limit of the Temperature sensor's operational range. |
298 |
Temp Upper Sensor Limit |
299 |
The upper limit of the Temperature sensor's operational range. |
300 |
Temperature Units |
301 |
Temperature Value |
302 |
The digital value representing Temperature. |
303 |
Temperature Percent Range |
304 |
Current percentage of the full scale value for Temperature analog output. |
305 |
Temperature Range Lower Value |
306 |
The lower limit of the analog Temperature signal. |
307 |
Temperature Range Upper Value |
308 |
The upper limit of the analog Temperature signal. |
309 |
Temperature Sensor Serial # |
310 |
Unique serial number for this Field Devices Temperature sensor. |
311 |
Temperature Xfer Func |
312 |
Setpoint A/I Alarm Code |
313 |
Sets the number of LED flashes used to represent the activation of a Setpoint alarm. |
314 |
Setpoint Alarm Behavior |
315 |
Action taken by the Field Device and applied to flow when a Setpoint alarm condition occurs. |
316 |
Setpoint A/I Value |
317 |
Digital representation of the analog input signal (milliamps) for Setpoint. |
318 |
Setpoint Digital Damping Value |
319 |
Setpoint Minimum Span |
320 |
The minimum allowable delta between the Setpoint Range Upper and Lower values. |
321 |
Setpoint Lower Sensor Limit |
322 |
The lower limit of the analog Setpoint input signal. |
323 |
Setpoint Upper Sensor Limit |
324 |
The upper limit of the analog Setpoint input signal. |
325 |
Setpoint Ctrls |
326 |
Setpoint input is an externaly generated signal used to the drive the device's output. This variable is used to select which dymanic variable will be controled via Setpoint. |
327 |
PV |
328 |
SV |
329 |
Setpoint Units |
330 |
Setpoint Value |
331 |
The digital value representing the input signal for Setpoint. |
332 |
Setpoint Percent Range |
333 |
Current percentage of the full scale value for Setpoint's analog input. |
334 |
Setpoint Range Lower Value |
335 |
Setpoint Range Upper Value |
336 |
Setpoint Sensor Serial # |
337 |
Unique serial number for this Field Devices Setpoint analog to digital sensor. |
338 |
Setpoint Xfer Func |
339 |
Setpoint Low Flow Cutoff |
340 |
Minimum value of the analog input required before a non-zero Setpoint will be computed. |
341 |
Trim Zero |
342 |
Local variable used to capture the user input for Zero Offset. |
343 |
Trim Full Scale |
344 |
Local variable used to capture the user input for Full Scale Offset. |
345 |
A/O Type |
346 |
This device's analog output operating range. |
347 |
0 - 5 Volts |
348 |
4 - 20 mA |
349 |
0 - 20 mA |
350 |
Slug Units |
351 |
Slug Flow Alarm Code |
352 |
Sets the number of LED flashes used to represent the activation of a Slug Flow alarm. |
353 |
Diag Units |
354 |
Diagnostic Alarm Code |
355 |
Sets the number of LED flashes used to represent the activation of a Diag alarm. |
356 |
Home Menu |
357 |
write_variables |
358 |
Hot Key Menu |
359 |
Device Setup |
360 |
Process Variables |
361 |
Diags and Services |
362 |
Basic Setup |
363 |
Detailed Setup |
364 |
Analog I/O Confg |
365 |
PV A/O Config |
366 |
SV A/O Config |
367 |
Setpt A/I Confg |
368 |
Config Alarms |
369 |
Hart Rev Info |
370 |
Sensor Data |
371 |
Device Info |
372 |
Configure Alarm |
373 |
Primary A/O |
374 |
Secondary A/O |
375 |
A/I Setup |
376 |
Process Damping |
377 |
Alarms & Warnings |
378 |
Diag Results |
379 |
Sensor Status |
380 |
Valve Operations |
381 |
Process Var Units |
382 |
Display Device Status |
383 |
Displays an expanded view of all device status conditions reported by the Field Device. |
384 |
Valve Drive Data |
385 |
Refreshes variables associated with the Valve Drive dynamic data. |
386 |
Update Xmitter Variable Units |
387 |
Read the type of all units converters assigned to all Xmitter Variable. |
388 |
Confirm Update to Xmitter Variable Units |
389 |
Confirm Update of all Xmitter Variable Units Converters to the user selected types. |
390 |
Write Valve Override State |
391 |
Method created so command could be added to an EDIT_DISPLAY. |
392 |
Force reading Primary Analog data |
393 |
Write Primary and Secondary Analog Data |
394 |
Force reading Secondary Analog data |
395 |
Write Secondary Analog Data |
396 |
Force reading Setpoint Analog data |
397 |
Write Setpoint Analog Input Data |
398 |
Read Process Variables Damping Values |
399 |
Confirm Write Process Varariables Damping Values |
400 |
PV A/O Select |
401 |
Sets the Primary Analog Output mode to either 4-20 mA, 0-20 mA or 0-5 Volts. |
402 |
PV Exit Fixed O/P Abort |
403 |
Restores the Primary Analog Output to normal operating mode |
404 |
PV A/O Trim Zero |
405 |
Set the Primary Analog Output Trim Zero value. |
406 |
PV A/O Trim Full |
407 |
Set the Primary Analog Output Trim Full Scale value. |
408 |
SV A/O Select |
409 |
Sets the Secondary Analog Output mode to either 4-20 mA, 0-20 mA or 0-5 Volts. |
410 |
SV Exit Fixed O/P Abort |
411 |
Restores the Analog Output to normal operating mode |
412 |
SV A/O Trim Zero |
413 |
Set the Secondary Analog Output Trim Zero value. |
414 |
SV A/O Trim Full |
415 |
Set the Secondary Analog Output Trim Full Scale value. |
416 |
A/I Trim Zero |
417 |
Set the Analog Input Trim Zero value. |
418 |
A/I Trim Full |
419 |
Set the Analog Input Trim Full Scale value. |
420 |
Zero Sensor |
421 |
Preform a zero of the device's sensor under zero flow conditions. "User Function" |
422 |
Read Device Information |
423 |
Method for updating tag, descriptor, message, date, manufacturer ID, device ID, Model Number, Serial Number and Sensor Serial Number. |
424 |
Alarm Configurator |
425 |
Method for configuration of Field Device's individual alarm parameters. |
426 |
Reset Alarms |
427 |
Forces the device to clear all resetable alarms. |
428 |
Update Alarms and Warnings |
429 |
Parses bit assignments from xmtr specific status bytes to individual alarms and warnings. |
430 |
Update Diagnostics |
431 |
Refreshes variables associated with the Diagnostic data. |
432 |
DSP Sensor Data |
433 |
Refreshes variables associated with the Digital Signal Processor Sensor data. |
434 |
Update Digital Signal Processor Sensor Status |
435 |
This method gathers status associated with the Digital Signal Processor Sensor. |
436 |
Parse Firmware Revision |
437 |
Converts integer value for DspFirmwareRev to a decimal representation. |
438 |
Polling Address |
439 |
Writes the polling address to identify a Field Device and control analog output. ZERO = Field Device controls analog output. 1 to 15 = Field Device analog output disabled. |
440 |
Transmitter Specific Command Error |
441 |
No alarms existed when the command was received. |
442 |
Secondary Variable does not support separate units for the variable and its ranges. |
443 |
Secondary Variable has not been assigned in the device. |
444 |
Units Selection is not valid for the Transmitter Variable currently assigned to the Secondary Variable. |
445 |
Invalid State requested. |
446 |
MASS |
447 |
DENS |
448 |
VOLU |
449 |
TEMP |
450 |
SLUG |
451 |
DIAG |
452 |
Alarm Config |
453 |
Select Alarm: |
454 |
Severity |
455 |
Al Ltch Enable |
456 |
Lo Lim |
457 |
Hi Lim |
458 |
Delay |
459 |
Device Alarms and Warnings |
460 |
# Act Alarms |
461 |
Vol Flow |
462 |
Undefined6 |
463 |
Undefined7 |
464 |
Undefined8 |
465 |
DBase Init |
466 |
Pwr Fail |
467 |
Inter Temp |
468 |
Reserved13 |
469 |
Reserved14 |
470 |
Reserved15 |
471 |
Reserved16 |
472 |
# Act Warnings |
473 |
Device Diagsnostic Failures |
474 |
# Diags Failed |
475 |
Undef Diag |
476 |
Cal Diag |
477 |
ADC Diag |
478 |
Sensor Diag |
479 |
EEProm Diag |
480 |
Flash Mem |
481 |
RAM Diag |
482 |
Digital Signal Processor Sensor Status |
483 |
# Asserted |
484 |
Undef Bit1 |
485 |
RTD Fail |
486 |
Drv Satur |
487 |
Pickoff Sat |
488 |
Sensor Down |
489 |
Delta T O/F |
490 |
Undef Bit |
491 |
Freq Error |
492 |
Undef Bit9 |
493 |
Undef Bit10 |
494 |
EEProm Fail |
495 |
Undef Bit12 |
496 |
Undef Bit13 |
497 |
Undef Bit14 |
498 |
Undef Bit15 |
499 |
Undef Bit16 |
500 |
Stpt |
501 |
Dynamic Variables |
502 |
TV |
503 |
QV |
504 |
Units |
505 |
A/O |
506 |
Al Behav |
507 |
Specifies the desired output value during an alarm condition. |
508 |
Rng |
509 |
Rng Units |
510 |
DENSITY |
511 |
Den |
512 |
VOLUME FLOW |
513 |
Vol |
514 |
A/O Not Supported |
515 |
TEMPERATURE |
516 |
Setpoint Input |
517 |
|
518 |
A/I |
519 |
Range |
520 |
L/Cut |
521 |
FMU860 |
522 |
DT |
523 |
DVC |
524 |
FCX |
525 |
AS800 |
526 |
340T |
527 |
340C |
528 |
344 |
529 |
Siemens Micro K |
530 |
SITRANS L |
531 |
SIPAN PH |
532 |
SITRANS P |
533 |
75SMT |
534 |
UNIDELTA |
535 |
8320 |
536 |
SX5100 |
537 |
TSV175 |
538 |
DMU |
539 |
3780 |
540 |
BM70 |
541 |
8u |
542 |
Use the HotKey to check for more Diagnostic, Alarm or Device Status indications. |
543 |
Valve Drive data NOT read. |
544 |
Transmitter Variable One NOT read. |
545 |
Transmitter Variable Two NOT read. |
546 |
Transmitter Variable Three NOT read. |
547 |
Transmitter Variable Four NOT read. |
548 |
Transmitter Variable Five NOT read. |
549 |
Transmitter Variable One Units NOT written. |
550 |
Transmitter Variable Two Units NOT written. |
551 |
Transmitter Variable Three Units NOT written. |
552 |
Transmitter Variable Four Units NOT written. |
553 |
Density Units not supported by Setpoint, Transmitter Variable Five Units NOT written. |
554 |
Mass Units not supported by Setpoint, Transmitter Variable Five Units NOT written. |
555 |
Transmitter Variable Five Units NOT written. |
556 |
Enter the required Valve Drive value as a percent of full scale. |
557 |
Valve Drive data NOT written. |
558 |
Primary Analog Output Current and Percent of Range NOT read. |
559 |
Primary Analog Output Information NOT read. |
560 |
Primary Alarm Behavior value NOT read. |
561 |
Primary Analog Output data NOT written. |
562 |
Primary Alarm Behavior value NOT writen. |
563 |
Secondary Analog Output Current and Percent of Range NOT read. |
564 |
Secondary Analog Output Information NOT read. |
565 |
Secondary Alarm Behavior value NOT read. |
566 |
Secondary Analog units type NOT written. |
567 |
Secondary Analog Range Values NOT written. |
568 |
Secondary Alarm Behavior value NOT writen. |
569 |
Setpoint Low Flow Cutoff NOT read. |
570 |
Setpoint Current and Percent of Range NOT read. |
571 |
Setpoint Range Values NOT read. |
572 |
Setpoint Units NOT written. |
573 |
Setpoint Low Flow Cutoff NOT written. |
574 |
Setpoint Current and Percent of Range NOT written. |
575 |
Primary Damping Value set to nearest possible value. |
576 |
Primary Variable Damping Value NOT read. |
577 |
Secondary Damping Value set to nearest possible value. |
578 |
Secondary Variable Damping Value NOT read. |
579 |
Primary Variable Damping Value NOT set. |
580 |
Secondary Variable Damping Value NOT set. |
581 |
Select operating range for the PV Analog Output. |
582 |
4-20 mA;Exit |
583 |
Operation aborted,
returning to
previous menu. |
584 |
Primary Analog Output configuration values NOT set. |
585 |
ERROR: Primary Analog Output NOT returned to normal operation. |
586 |
Primary Analog Output returned to normal operation. |
587 |
Field Device will be placed in Fixed A/O Mode to change values, confirm: |
588 |
YES;NO |
589 |
Primary Trim Zero operation aborted. |
590 |
Primary Trim Zero NOT set. |
591 |
Enter the Primary A/O reference meter's displayed value? |
592 |
Command Aborted, Field Device still in Fixed Analog Output Mode. |
593 |
Is the result of the Trim acceptable? |
594 |
Primary Trim Full Scale operation aborted. |
595 |
Primary Full Scale value NOT set. |
596 |
Select operating range for the SV Analog Output. |
597 |
Secondary Analog Output configuration values NOT set. |
598 |
ERROR: Secondary Analog Output NOT returned to normal operation. |
599 |
Secondary Analog Output returned to normal operation. |
600 |
Secondary Trim Zero operation aborted. |
601 |
Secondary Trim Zero NOT set. |
602 |
Enter the Secondary A/O reference meter's displayed value? |
603 |
Secondary Trim Full Scale operation aborted. |
604 |
Secondary Full Scale value NOT set. |
605 |
Have you set the external Analog Input to the desired trim zero? |
606 |
Set the external analog input to the desired value and re-enter this menu selection. |
607 |
Trim Zero NOT set. |
608 |
Have you set the external Analog Input to the desired Full Scale value? |
609 |
Full Scale value NOT set. |
610 |
Have you taken measures to insure zero flow through the device? |
611 |
Eliminate flow through the device and re-enter this menu selection to complete User Zero. |
612 |
Field Device NOT zero'ed. |
613 |
Tag NOT read. |
614 |
Message NOT read. |
615 |
Manufacturer and device ID NOT read. |
616 |
Model Number NOT read. |
617 |
Serial Number NOT read. |
618 |
Primary Sensor Serial Number NOT read. |
619 |
Alarm Configuration Data NOT read. |
620 |
Alarm Configuration Data NOT written. |
621 |
Alarms NOT cleared. |
622 |
All Resetable
Alarms Cleared. |
623 |
Gathering
Alarm and Warning
data. |
624 |
Alarm & Warning
status NOT updated. |
625 |
Gathering
Diagnostic Results. |
626 |
Dignostic results
NOT updated. |
627 |
Gathering
Sensor Info. |
628 |
DSP Sensor data
NOT updated. |
629 |
Gathering
Sensor Status. |
630 |
DSP Sensor sataus
NOT updated. |
631 |
Select the desired polling address from the range of 0 to 15. |
632 |
Polling address NOT written. |