0 |
Zero |
1 |
Reset the gas reading to 0 (clean air for all gases except O2 and CO2). |
2 |
Inhibit mode |
3 |
Set or clear inhibit mode. |
4 |
Clear Inhibit mode |
5 |
Clear inhibit mode. |
6 |
Pellistor mode |
7 |
.2f |
8 |
.1f |
9 |
.0f |
10 |
Calibration |
11 |
Calibrate the gas reading to an applied gas level. |
12 |
Zero Trim |
13 |
Trim analogue output 4mA point. |
14 |
Span Adjust |
15 |
Span adjust analogue output to give 20mA with 100% target gas. |
16 |
Clear ramp mode |
17 |
Clear (exit) ramp mode. |
18 |
Ramp auxiliary method |
19 |
Auxiliary method to assist with Ramp with and without alarm. |
20 |
Ramp No Alarm |
21 |
Ramp (manual control) of analogue output for test without alarm relay activation. |
22 |
Ramp With Alarm |
23 |
Ramp (manual control) of analogue output for test with alarm relay activation. |
24 |
Date and Time |
25 |
Set time and date in instrument. |
26 |
Acknowledge Alarms |
27 |
Reset latched alarms. |
28 |
Speedy Bump |
29 |
Check alarm 1 can be exceeded in test time; use Abort to terminate purge when in clean air. |
30 |
Smart Bump |
31 |
Check gas level between defined limits at end of test; use Abort to terminate purge when in clean air. |
32 |
Set |
33 |
Inhibit loop current and alarm relays. |
34 |
Clear |
35 |
Remove inhibit of loop current and alarm relays. |
36 |
Relay Test |
37 |
Test alarm and fault relays. |
38 |
Device Reset |
39 |
Reset XgardIQ and perform all power-on tests. |
40 |
XgardIQ Maintenance |
41 |
XgardIQ Offline |
42 |
XgardIQ Process Variables |
43 |
XgardIQ Diagnostics |
44 |
XgardIQ |
45 |
Inhibit |
46 |
Set or clear inhibit state. |
47 |
Readings |
48 |
Various parameters monitor by the XgardIQ |
49 |
Analogue Output |
50 |
Options to allow adjustment and test of the analogue output system. |
51 |
Alarm 1 |
52 |
Options to view and modifiy alarm 1 parameters. |
53 |
Alarm 2 |
54 |
Options to view and modifiy alarm 2 parameters. |
55 |
Alarm and Relay |
56 |
Options to view and adjust alarm parameters. |
57 |
Bump Test |
58 |
Options to view and adjust bump test parameters and perform tests. |
59 |
Configure |
60 |
View or modify configuration. |
61 |
Test |
62 |
Options for instrument test. |
63 |
Set Ramp (manual) mode on analogue output. |
64 |
Test sensor response to gas. |
65 |
Revision Numbers |
66 |
Review revision information associated with the field device. |
67 |
HART |
68 |
Review data and information associated with the field device. |
69 |
Review and modify information associated with the field device. |
70 |
Sensitivity |
71 |
Estimated sensor sensitivity, including quality of the information. |
72 |
Information |
73 |
Instrument status, including temperature, supply V, due dates, +ve Safety and other review information. |
74 |
+ve Safety |
75 |
Set +ve safety status data. |
76 |
Status |
77 |
Set device status. |
78 |
Current time and date. |
79 |
Due Dates |
80 |
Dates by which the next bump test and calibration should be performed. |
81 |
About |
82 |
Information about the XgardIQ. |
83 |
Firmware |
84 |
Firmware versions of the XgardIQ components. |
85 |
Fitted Modules |
86 |
Optional modules fitted to XgardIQ. |
87 |
Sensor |
88 |
Details of the fitted sensor module. |
89 |
Cross Gases |
90 |
Gases and associated levels that can be used for a cross calibration or bump. |
91 |
Serial Number |
92 |
Password |
93 |
Options associated with the password lock of instrument modification. |
94 |
Crowcon |
95 |
Configuration locked |
96 |
Configuration locked by password protection. |
97 |
Status 0 |
98 |
Initialising |
99 |
Gas alarm 1 |
100 |
Gas alarm 2 |
101 |
4-20mA signal inhibited |
102 |
4-20mA signal in ramp mode |
103 |
Alarm and fault relays inhibited |
104 |
Alarm relays in test mode |
105 |
Fault relay in test mode |
106 |
Status 1 |
107 |
Sensor hardware fault |
108 |
Transmitter hardware fault |
109 |
Sensor firmware fault |
110 |
Transmitter firmware fault |
111 |
Undefined fault in sensor |
112 |
Unused status 1 |
113 |
Production failure |
114 |
Analogue output feedback fault |
115 |
Status 2 |
116 |
Sensor measurement fault |
117 |
Watchdog test failure |
118 |
Unused status 2 |
119 |
Sensor version fault |
120 |
Sensor missing |
121 |
Unused status 3 |
122 |
Unused status 4 |
123 |
Gas calibration required |
124 |
Status 3 |
125 |
Unused status 5 |
126 |
Gas calibration data error |
127 |
Gas characterization error |
128 |
Unused status 6 |
129 |
Unused status 7 |
130 |
Sensor temperature fault |
131 |
Gas reading under range |
132 |
Gas reading over range |
133 |
Status 4 |
134 |
Optics obscured |
135 |
Sensor over gassed |
136 |
Unused status 8 |
137 |
Unused status 9 |
138 |
mA output calibration error |
139 |
Transmitter characterization error |
140 |
Unused status 10 |
141 |
Unused status 11 |
142 |
Status 5 |
143 |
Supply voltage low |
144 |
Supply voltage high |
145 |
Transmitter temperature fault |
146 |
Tramsmitter system fault |
147 |
Sensor system warning |
148 |
Log data error |
149 |
Log data lost |
150 |
Unused status 12 |
151 |
Status 6 |
152 |
Display missing |
153 |
Display hardware fault |
154 |
Display firmware fault |
155 |
Language data error |
156 |
Display temperature fault |
157 |
Display system warning |
158 |
Unused status 13 |
159 |
Biased sensor battery failure |
160 |
Status 7 |
161 |
Sensor changed; different gas |
162 |
Sensor changed; same gas |
163 |
Sensor changed; changed rejected |
164 |
Optics nearly obscured |
165 |
Unused status 14 |
166 |
Time/data lost |
167 |
Calibration due |
168 |
Calibration due soon |
169 |
Status 8 |
170 |
Bump test due |
171 |
Outputs inhibited |
172 |
Unused status 15 |
173 |
Internal data error |
174 |
+ve safety data lost |
175 |
Configuration update failed |
176 |
Unused status 16 |
177 |
Unused status 17 |
178 |
Signal Range |
179 |
0.1f |
180 |
Current Date |
181 |
Current Date based upon the real-time clock in the XgardIQ. |
182 |
Current Time |
183 |
Current Time based upon the real-time clock in the XgardIQ. |
184 |
Set Clock Date |
185 |
Date to set the real-time clock in the field device to, or date that the real-time clock was last set. |
186 |
Set Clock Time |
187 |
Time to set the real time clock in the field device to, or time that the real-time clock was last set. |
188 |
OK |
189 |
Failed: Invalid selection. |
190 |
Failed: XgardIQ received too few bytes. |
191 |
Failed: Password protected. Unlock and re-try. |
192 |
Failed: Access restricted. |
193 |
Sensor successfully zeroed. |
194 |
Zero in progress. |
195 |
Zero succeeded; calibration now required. |
196 |
Failed: Sensor or detector failure. |
197 |
Failed: Optics obscured. |
198 |
Failed: Sensor temperature out of limits. |
199 |
Failed: Pellistor in saver mode. |
200 |
Failed: Sensor supply out of limits. |
201 |
Failed: Reading too far from clean air. |
202 |
Failed: Sensor module missing. |
203 |
Internal failure in XgardIQ! Check status and re-try. |
204 |
Failed: Sensor under/over range. |
205 |
Failed: Bump test or calibration in progress. |
206 |
Failed: Sensor not purged with N2. |
207 |
Sensor successfully calibrated. |
208 |
Failed: Gain low, too much gas applied? |
209 |
Failed: Gain high, too little gas applied? |
210 |
Calibration in progress. |
211 |
Failed: No calibration gas applied. |
212 |
Failed: Production error. |
213 |
Failed: Bump test or zero in progress. |
214 |
Failed: Calibration level invalid. |
215 |
Transmitter Serial Number |
216 |
Serial number of the XgardIQ transmitter. |
217 |
Sensor Serial Number |
218 |
Serial number of the XgardIQ sensor module. |
219 |
Main Firmware Version |
220 |
Software version of the transmitter (main) component of the XgardIQ. |
221 |
Sensor Firmware Version |
222 |
Software version of the XgardIQ sensor module. |
223 |
Display Firmware Version |
224 |
Software version of the transmitter component of the XgardIQ. |
225 |
Enable or disable use of HART password. |
226 |
Disabled |
227 |
Disable password protection |
228 |
Enabled |
229 |
Enable password protection |
230 |
Set Password |
231 |
Password required to unlock a HART password protected instrument. |
232 |
password |
233 |
Password to Unlock |
234 |
Password required to unlock HART password protected instrument. |
235 |
|
236 |
Password Lock |
237 |
Current state of password lock. |
238 |
Unlocked |
239 |
XgardIQ password unlocked - write functions are accessible |
240 |
Locked |
241 |
XgardIQ locked by password - unlock to access write functions |
242 |
On Threshold |
243 |
Alarm activiation level |
244 |
Off Threshold |
245 |
Alarm de-activiation level |
246 |
On Delay |
247 |
Delay (in seconds) to alarm activation once on-threshold crossed. |
248 |
Off Delay |
249 |
Delay (in seconds) to alarm de-activation once off-threshold crossed. |
250 |
Latching |
251 |
Specifies if alarm 1 is latched once alarm condition clears. |
252 |
Relay |
253 |
Specifies default state of relay. |
254 |
De-energised |
255 |
Energised |
256 |
Direction |
257 |
Specifies whether alarm is rising or falling. |
258 |
Falling |
259 |
Rising |
260 |
Failed: Invalid alarm selection. |
261 |
Failed: Invalid data or alarm selection |
262 |
Gas Name |
263 |
Configured name of measured gas. |
264 |
Gas Units |
265 |
Configured units of measured gas. |
266 |
ID String |
267 |
XgardIQ identification string. |
268 |
Relays Fitted? |
269 |
Optional fitted component. |
270 |
Not fitted |
271 |
Optional relay board is not fitted. |
272 |
Fitted |
273 |
Optional relay board is fitted. |
274 |
Foundation Fieldbus Fitted? |
275 |
Optional Foundation Fieldbus board is not fitted. |
276 |
Optional Foundation Fieldbus board is fitted. |
277 |
Gas sensor module type. |
278 |
None |
279 |
Toxic |
280 |
Oxygen |
281 |
Biased toxic |
282 |
Pellistor |
283 |
Infra-red |
284 |
MOS |
285 |
PID |
286 |
IRmax |
287 |
Not CO2 |
288 |
CO2 |
289 |
Failed: Passed parameter too large. |
290 |
Failed: Passed parameter too small. |
291 |
Failed: Loop current not active (device in multi-drop mode). |
292 |
Alarms acknowledged |
293 |
Zero Suppression |
294 |
Level of suppression used to reduced noise around the clean air value. |
295 |
Light |
296 |
Medium |
297 |
Heavy |
298 |
Failed: Invalid data. |
299 |
Saver disabled |
300 |
Saver enabled |
301 |
Pellistor restart request successful. |
302 |
Failed: Invalid option. |
303 |
Gas Sense Time |
304 |
Time instrument will wait for initial gas response before test start. Valid range 5 to 300 seconds. |
305 |
Bump Test Time |
306 |
Maximum test time for speedy bump; total test time for smart bump. Valid range 5 to 300 seconds. |
307 |
Smart Bump Lower Limit |
308 |
Lowest gas reading allowed to pass a smart bump. Valid range 0 to sensor range. |
309 |
Smart Bump Upper Limit |
310 |
Highest gas reading allowed to pass a smart bump. Valid range 0 to sensor range. |
311 |
Bump test not in progress. |
312 |
Waiting for initial gas response. |
313 |
Test in progress |
314 |
Test passed - purging test gas. |
315 |
Test failed - purging gas. |
316 |
Test failed - no purge required. |
317 |
Poll status |
318 |
Speedy test |
319 |
Smart test |
320 |
Terminate test |
321 |
Bump test passed. |
322 |
Failed: Invalid test option. |
323 |
Failed: Password locked; unlock and re-try. |
324 |
Failed: Gas reading too low. |
325 |
Failed: Gas reading too high. |
326 |
Failed: Zero, bump or calibration in progress. |
327 |
Bump test in progress. |
328 |
Failed: Check instrument status. |
329 |
Failed: Gas present at test start. |
330 |
Failed: No gas response. |
331 |
Failed: No alarm during test. |
332 |
Failed: Zero or calibration in progress. |
333 |
Aborted: user request. |
334 |
Bump Due Date |
335 |
Instrument is due for bump test before the end of this date. |
336 |
Calibration Due Date |
337 |
Instrument is due for calibration before the end of this date. |
338 |
Relay Test State. |
339 |
State of alarm and fault relay test. |
340 |
Relay test inactive. |
341 |
Alarm relays: both inactive. |
342 |
Alarm relays: 1 active |
343 |
Alarm relays: 2 active. |
344 |
Alarm relays: both active. |
345 |
Fault relay: active. |
346 |
Fault relay: inactive. |
347 |
Relay test state set. |
348 |
Failed: Relay module not fitted. |
349 |
Fault Level |
350 |
mA signal level when in fault state. |
351 |
1mA |
352 |
2mA |
353 |
3mA |
354 |
Warning Level |
355 |
mA signal level when in warning state. |
356 |
Inhibit Level |
357 |
mA signal level when in operational inhibit state. |
358 |
Clean air |
359 |
Power-on Inhibit |
360 |
mA signal level when in power-on inhibit state. |
361 |
Failed: XgardIQ received too few bytes |
362 |
Number of Cross Gases |
363 |
Number of gases for cross calibration and bump |
364 |
Gas Range |
365 |
Full measurement range of gas sensor. |
366 |
Target gas name. |
367 |
Target gas measurement units. |
368 |
Cross Gas 1 Level |
369 |
Level of cross gas to apply for cross calibration and bump. |
370 |
Cross Gas 1 Name |
371 |
Gas to be used for cross calibration and bump. |
372 |
Cross Gas 1 Units |
373 |
Units of gas to be used for cross calibration and bump. |
374 |
Cross Calbration Factor 1 |
375 |
Relative cross sensitivity to target gas. |
376 |
Cross Gas 2 Level |
377 |
Cross Gas 2 Name |
378 |
Cross Gas 2 Units |
379 |
Estimated sensor sensitivity at last successful calibration. |
380 |
Sensitivity Quality |
381 |
Quaility of sensitivity estimate. |
382 |
Unknown, low |
383 |
Sensitivity low - either sensor failed or last calibration incorrectly peformed. |
384 |
Unknown, high |
385 |
Sensitivity high - last calibration incorrectly peformed. |
386 |
Sensitivity estimate is sound. |
387 |
Gas |
388 |
Measured gas level. |
389 |
Engineering unit associated with the measured gas level. |
390 |
%LEL |
391 |
percentage of lower explosive limit (%LEL) |
392 |
%vol |
393 |
volume of target gas as a percentage of volume (%vol) |
394 |
ppm |
395 |
parts per million (ppm) |
396 |
ppb |
397 |
parts per billion (ppb) |
398 |
Gas Class |
399 |
Gas PDQ |
400 |
Gas LS |
401 |
Gas Fmly stat |
402 |
Gas Dev fmly |
403 |
Sensor Range |
404 |
Gas LSL |
405 |
Gas min span |
406 |
Gas damp |
407 |
Gas serial number |
408 |
Gas lower trim |
409 |
Gas upper trim |
410 |
.3f |
411 |
Gas Trim support |
412 |
Gas Min lower trim |
413 |
Gas Max lower trim |
414 |
Gas Min upper trim |
415 |
Gas Max upper trim |
416 |
Gas Min trim diff |
417 |
Sensor Obscuration |
418 |
Obscuration of the optics. |
419 |
Obscuration Units |
420 |
Sensor Obscuration Units- Engineering unit to be displayed with Sensor Obscuration. |
421 |
% |
422 |
Percentage obscuration |
423 |
+ve Safety 1 |
424 |
Conditions that have occurred that may have compromised the instrument's ability to accurately measure gas. |
425 |
Pellistor saver occurred |
426 |
Sensor temperature too low |
427 |
Sensor temperature too high |
428 |
+ve Safety 2 |
429 |
Conditions that indicate something has happened to the instrument that could have affected it. |
430 |
Loop mode disabled |
431 |
Fault state |
432 |
Warning state |
433 |
Unused status |
434 |
Failed: Busy with zero, calibrate or bump test. |
435 |
Obscuration Class |
436 |
Device_family |
437 |
Obscuration PDQ |
438 |
Obscuration LS |
439 |
Obscuration Dev Stat |
440 |
Obscuration USL |
441 |
Obscuration LSL |
442 |
Obscuration min span |
443 |
Obscuration damp value |
444 |
Obscuration snsr s/n |
445 |
Obscuration |
446 |
Optical obscuration |
447 |
Supply V |
448 |
Instrument supply voltage. |
449 |
Supply V Units |
450 |
Supply V Units- Engineering unit to be displayed with instrument supply voltage. |
451 |
Volts |
452 |
Supply voltage |
453 |
Supply V Class |
454 |
Device family |
455 |
Supply PDQ |
456 |
Supply LS |
457 |
Temp Dev Stat |
458 |
Supply USL |
459 |
Supply LSL |
460 |
Supply min span |
461 |
Supply damp value |
462 |
Temp snsr s/n |
463 |
Gas (no zero suppression) |
464 |
Measured gas level with no zero suppression. |
465 |
Gas units |
466 |
Sensor Temperature |
467 |
Temperature as measured by the sensor module. |
468 |
Temperature Units |
469 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
470 |
ºC |
471 |
Temperature |
472 |
Temperature Class |
473 |
Temperature PDQ |
474 |
Temperature LS |
475 |
Temperature Dev Stat |
476 |
Temperature USL |
477 |
Temperature LSL |
478 |
Temperature as measured by the sensor module |
479 |
temperature |
480 |
Transmitter Temperature |
481 |
Temperature as measured by the transmitter. |
482 |
Units |
483 |
Transmitter Temperature Units- Engineering unit to be displayed with Transmitter Temperature. |
484 |
Temperature as measured by the transmitter |
485 |
Gas (no suppression) |
486 |
Transmitter |
487 |
PV Analog Channel Saturated |
488 |
PV Analog Channel Fixed |
489 |
Wireless |
490 |
WirelessHART Device |
491 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
492 |
Primary |
493 |
Primary Analog Channel |
494 |
Secondary |
495 |
Secondary Analog Channel |
496 |
Tertiary |
497 |
Tertiary Analog Channel |
498 |
Quaternary |
499 |
Quaternary Analog Channel |
500 |
Quinary |
501 |
Quinary Analog Channel |
502 |
Critical Power Failure |
503 |
Lock all |
504 |
Trim not supported |
505 |
Configuration cannot be changed |
506 |
Locked by gateway |
507 |
Analog Input Channel |
508 |
Analog Output Channel |
509 |
Secondary Analog Channel Saturated |
510 |
Tertiary Analog Channel Saturated |
511 |
Quaternary Analog Channel Saturated |
512 |
Quinary Analog Channel Saturated |
513 |
Secondary Analog Channel Fixed |
514 |
Tertiary Analog Channel Fixed |
515 |
Quaternary Analog Channel Fixed |
516 |
Quinary Analog Channel Fixed |
517 |
Simulation active |
518 |
The device is in simulation mode and the level output is not representative of the process. |
519 |
Non-Volatile memory failure |
520 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
521 |
Volatile memory error |
522 |
The RAM memory check is invalid or maybe corrupt |
523 |
Watchdog reset executed |
524 |
A watchdog reset has been performed |
525 |
Voltage conditions out of range |
526 |
A voltage condition is outside its allowable range |
527 |
Environmental conditions out of range |
528 |
An internal or environmental condition is beyond acceptable limits. |
529 |
Electronic failure |
530 |
A hardware problem not related to the sensor has been detected. |
531 |
Subdevice list changed |
532 |
Duplicate master detected |
533 |
Capacity Denied |
534 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
535 |
Bandwidth allocation pending |
536 |
Block transfer pending |
537 |
Battery life |
538 |
Percent range |
539 |
Loop current |
540 |
Primary variable |
541 |
Secondary variable |
542 |
Tertiary variable |
543 |
Quaternary variable |
544 |
Read receive time |
545 |
Write date and time |
546 |
Non-Volatile Clock |
547 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
548 |
Clock Uninitialized |
549 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
550 |
No restrictions |
551 |
SI Only |
552 |
Restricted to SI Unit codes only |
553 |
Process automation device |
554 |
Discrete device |
555 |
Hybrid:Process automation+discrete |
556 |
I/O System |
557 |
WirelessHART Process automation device |
558 |
WirelessHART Discrete device |
559 |
WirelessHART Process automation+discrete |
560 |
WirelessHART Gateway |
561 |
WirelessHART Access point |
562 |
WirelessHART Process adapter |
563 |
WirelessHART Discrete adapter |
564 |
WirelessHART enabled handheld/portable maintenance tool |
565 |
Device Profile |
566 |
US |
567 |
United States of America |
568 |
JP |
569 |
Japan |
570 |
DE |
571 |
Germany |
572 |
FR |
573 |
France |
574 |
ES |
575 |
Spain |
576 |
RU |
577 |
Russian Federation |
578 |
CN |
579 |
People's Republic of China |
580 |
Secondary Master |
581 |
Primary Master |
582 |
Device Diagnostic Status 0 |
583 |
Device Diagnostic Status 1 |
584 |
I/O and Subdevice Status |
585 |
WirelessHART Status |
586 |
Time Set Option |
587 |
Real Time Clock Flags |
588 |
Country |
589 |
Country of intended device installation |
590 |
SI Unit Control |
591 |
Indicates if device should only display SI unit codes |
592 |
Time Stamp |
593 |
Relative time value on network |
594 |
8u |
595 |
Dynamic Variables Returned for Device Variables |
596 |
Command Response Truncated |
597 |
Configuration Change Counter Mismatch |
598 |
Status bytes mismatch |
599 |
8.3f |
600 |
WARNING: Abort only aborts the HART master.
Selected operation will still complete. |
601 |
Purge sensor with nitrogen and select OK when ready.
Gas level: %[D]{varGasNoSuppressValue} %{varGasCfgUnits} |
602 |
Ensure in clean air and select OK when ready.
Gas level: %[D]{varGasNoSuppressValue} %{varGasCfgUnits} |
603 |
Performing zero, please wait...0% complete. |
604 |
Performing zero, please wait...%[d]{varIntZeroProgress}% complete. |
605 |
Purge nitrogen from sensor and select OK when gas is cleared.
Gas level: %[D]{varGasNoSuppressValue} %{varGasCfgUnits} |
606 |
level1 |
607 |
%{varGasCfgName};%{varSensorXName_1} %{level1} %{varSensorXUnits_1} |
608 |
Select gas to use |
609 |
level2 |
610 |
%{varGasCfgName};%{varSensorXName_1} %{level1} %{varSensorXUnits_1};%{varSensorXName_2} %{level2} %{varSensorXUnits_2} |
611 |
Calibration gas to be applied (%{varGasCfgUnits}): |
612 |
Apply calibration gas of %{calGas} and select OK when ready.
Gas level: %[D]{varGasNoSuppressValue} %{varGasCfgUnits} |
613 |
Performing calibration, please wait...0% complete. |
614 |
Performing calibration, please wait...%[d]{varIntCalProgress}% complete. |
615 |
Purge gas from sensor and select OK when gas is cleared.
Gas level: %[D]{varGasNoSuppressValue} %{varGasCfgUnits} |
616 |
Successfully cross-calibrated to %{varXCalLvl1} %{varGasCfgUnits} %{varGasCfgName}. |
617 |
Successfully calibrated to %{varCalibrateLvl} %{varGasCfgUnits} %{varGasCfgName}. |
618 |
Loop current will be set to 4mA. |
619 |
mA;%{varGasCfgUnits} |
620 |
Select units for zero trim: |
621 |
Measured loop current (mA): |
622 |
Gas level at control panel (in %{varGasCfgUnits}) |
623 |
Loop current will be set to 20mA. |
624 |
Select units for span adjust: |
625 |
Measure loop current using accurate DVM.
Measured loop current (mA): |
626 |
Enter the gas level displayed by the control panel.
Measured gas level %{varGasCfgUnits}: |
627 |
Use what units for ramp? |
628 |
Enter mA output (0.0 to abort): |
629 |
editLvl |
630 |
Enter %{varGasCfgUnits} output (< 0 to abort): |
631 |
New date (mm/dd/yyyy): |
632 |
New time (hh:mm:ss): |
633 |
Alarms successfully acknowledged. |
634 |
level |
635 |
%{varGasCfgName};%{varSensorXName_1} %{level} %{varSensorXUnits_1} |
636 |
Ensure the sensor is in clean air and select OK when ready.
Gas level: %[D]{varGasNoSuppressValue} %{varGasCfgUnits} |
637 |
Waiting for gas response...
Gas level: %{varGasNoSuppressValue} %{varGasCfgUnits} (%[d]{varIntBumpProgress} seconds left). |
638 |
Performing test...
Gas level: %{varGasNoSuppressValue} %{varGasCfgUnits} (%[d]{varIntBumpProgress} seconds left). |
639 |
Remove applied gas...
Gas level: %{varGasNoSuppressValue} %{varGasCfgUnits}. |
640 |
Inhibit mode set. |
641 |
Inhibit mode cleared. |
642 |
Relay test to perform |
643 |
Test inactive; Alarm - both inactive; Alarm - 1 active; Alarm - 2 active; Alarm - both active; Fault - active; Fault - inactive |
644 |
Select OK to reset the device. |
645 |
Waiting for reset...%{i} |
646 |
Reset successful. |