0 |
FRC |
1 |
Fuji Instrument |
2 |
EEPROM 1 Sum Err in Device Informatiom and Parameters |
3 |
EEPROM 2 Sum Err in Special TC defined table |
4 |
EEPROM 3 Sum Err in Special RTD defined table |
5 |
EEPROM 4 Sum Err in Special Linearizer defined table |
6 |
|
7 |
EEPROM ALL SumEr |
8 |
EEPROM Hard Err |
9 |
Electronics Failure |
10 |
Sensor Connection |
11 |
Process sensor |
12 |
Term temp sensor |
13 |
LCD Display mode |
14 |
.2f |
15 |
.3f |
16 |
.5f |
17 |
8.3f |
18 |
Terminal Temperature Sensor Variable Value - Digital value that changes magnitude with respect to time with no user interventation |
19 |
Terminal Temperature Sensor Unit - Engineering unit to be displayed with the terminal temperature values representation |
20 |
SV Snsr Unit |
21 |
7d |
22 |
Dynamic Variables |
23 |
Wires |
24 |
Self test |
25 |
Master reset |
26 |
Loop Warming Var |
27 |
Write variables |
28 |
Snsr Type |
29 |
Pt 100 |
30 |
Pt 100 (IEC/DIN/JIS'97) |
31 |
Millivolt |
32 |
DC mV |
33 |
TC B |
34 |
T/C Type B |
35 |
TC E |
36 |
T/C Type E |
37 |
TC W |
38 |
T/C Type WRe 5-26 |
39 |
TC J |
40 |
T/C Type J |
41 |
TC K |
42 |
T/C Type K |
43 |
TC N |
44 |
T/C Type N |
45 |
TC R |
46 |
T/C Type R |
47 |
TC S |
48 |
T/C Type S |
49 |
TC T |
50 |
T/C Type T |
51 |
TC L |
52 |
T/C Type L |
53 |
TC U |
54 |
T/C Type U |
55 |
TC P |
56 |
T/C Type P(Platinel 2) |
57 |
TC PR |
58 |
T/C Type PR |
59 |
Snsr Wires |
60 |
CJ Compensation Mode Switch - Cold Junction Compensation Mode which becomes effective at Thermcouple input sensor |
61 |
CJ Comp. |
62 |
Burnout |
63 |
Input Sensor Calibration Mode |
64 |
Cal. Mode |
65 |
Reset |
66 |
Zero Cal. |
67 |
Span Cal. |
68 |
PV Cal. Unit |
69 |
Calibration Value |
70 |
Zero Calibration Point |
71 |
Zero Calibration Value |
72 |
Span Calibration's Gain |
73 |
Invalid Calibration - Calibrated gain is TOO LARGE or TOO SMALL |
74 |
Invalid Calibration - data is TOO LARGE or TOO SMALL |
75 |
Input data error |
76 |
Invalid Calibration data units |
77 |
LCD Display Mode |
78 |
LCD mode |
79 |
PV - EU |
80 |
PV - % |
81 |
AO - % |
82 |
AO - EU |
83 |
Term temp |
84 |
Select Snsr |
85 |
Snsr Zero Cal. |
86 |
Snsr Zero Cal.- Make the sensor input the new input reference. |
87 |
Snsr Span Cal. |
88 |
Snsr Span Cal. - Make the sensor input the new input reference. |
89 |
Reset Cal. |
90 |
Reset Cal.- Reset the all sensor input calibration data. |
91 |
FMU860 |
92 |
DT |
93 |
DVC |
94 |
FCX |
95 |
AS800 |
96 |
340T |
97 |
340C |
98 |
344 |
99 |
Siemens Micro K |
100 |
SITRANS L |
101 |
SIPAN PH |
102 |
SITRANS P |
103 |
75SMT |
104 |
UNIDELTA |
105 |
8320 |
106 |
SX5100 |
107 |
TSV175 |
108 |
DMU |
109 |
3780 |
110 |
BM70 |
111 |
8u |
112 |
low |
113 |
high |
114 |
tmp_av |
115 |
Device maybe stuck in Master Reset. |
116 |
Self test OK |
117 |
About to Preform Master Reset |
118 |
Master Reset in
progress please wait |
119 |
Master reset OK |
120 |
Select sensor type |
121 |
RTD;Millivolt;TC |
122 |
Select wires |
123 |
2 wires;3 wires;4 wires |
124 |
Select RTD sensor |
125 |
Select TC sensor |
126 |
TC B;TC E;TC J;TC K;TC N;TC R;TC S;TC T;TC W;TC U;TC L;TC P;TC PR |
127 |
Select POT sensor |
128 |
POT 4000;POT 2500;POT 1200;POT 600;POT 300;POT 150 |
129 |
Custom TC Table not defined! |
130 |
Custom RTD Table not defined! |
131 |
The sensor type not supported! |