Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
clear_lin_table | 40FF | Clear Table | Selecting CLEAR TABLE will completely erase all values from the Linearization Table. | msrc_UNKNOWN | Details |
reload_lin_table | 4100 | Restore Table | Selecting RESTORE TABLE will reinstall the values of a Linearization Table that have been stored in the Back Up file of the device. | msrc_UNKNOWN | Details |
backup_lin_table | 4101 | Save Table | Selecting SAVE TABLE will store all of the values in the Linearization Table to a Back Up file in the EPROM of the device. | msrc_UNKNOWN | Details |
method_lin_table_specificpoint_new2 | 4103 | Set LIN Points | Configures the LIN points mode, LIN Input points, LIN Output points and LIN points status. | msrc_UNKNOWN | Details |
login_standard_password | 4365 | Login Standard | Login to Standard access level. | msrc_UNKNOWN | Details |
login_advanced_password | 4366 | Login Advanced | Login to Advanced access level. | msrc_UNKNOWN | Details |
login_Service_password | 4367 | Login Service | Login to Service access level. | msrc_UNKNOWN | Details |
logout_access_level | 4368 | Logout Access Level | Return to lowest access level. | msrc_UNKNOWN | Details |
change_standard_password | 4369 | Change Standard Password | Change password for Standard access level | msrc_UNKNOWN | Details |
change_advanced_password | 436A | Change Advanced Password | Change password for Advanced access level | msrc_UNKNOWN | Details |
reset_output_trimming | 436B | Reset D/A Trim | Reset the device D/A trim points to factory settings. | msrc_UNKNOWN | Details |
reset_passwords_defaults | 436C | Reset Passwords to Default | Reset Standard and Advanced Passwords to the factory defaults. | msrc_UNKNOWN | Details |
wet_calibration | 436D | Wet Calibration | Calibration performed by writing the level value to the device and having the device measure and store the associated sensor value. | msrc_UNKNOWN | Details |
wet_calibration_level | 436E | Wet Calibration - Level | Calibration performed by writing the level value to the device and having the device measure and store the associated sensor value. | msrc_UNKNOWN | Details |
wet_calibration_level_lowerpoint | 436F | Set Lower Level Point | Calibration performed by writing the lower level value to the device and having the device measure and store the associated sensor value. | msrc_UNKNOWN | Details |
wet_calibration_level_upperpoint | 4370 | Set Upper Level Point | Calibration performed by writing the upper level value to the device and having the device measure and store the associated sensor value. | msrc_UNKNOWN | Details |
clear_diagnostics_history | 4371 | Clear Diagnostics History | Clear the diagnostics history in the device. | msrc_UNKNOWN | Details |
reset_software_write_protection | 4372 | Reset Software Write Protection | Turnoff Software Write Protection. | msrc_UNKNOWN | Details |
read_pv_map | 4373 | msrc_UNKNOWN | Details | ||
read_lin_urv_lrv | 4374 | msrc_UNKNOWN | Details | ||
read_pv_urv_lrv | 4375 | msrc_UNKNOWN | Details | ||
read_accesslevel | 4376 | msrc_UNKNOWN | Details | ||
restart_message_leveldeviceype | 4377 | msrc_UNKNOWN | Details | ||
restart_message_probelength | 4378 | msrc_UNKNOWN | Details | ||
restart_message_pulsewidth | 4379 | msrc_UNKNOWN | Details | ||
restart_message_mountorientation | 437A | msrc_UNKNOWN | Details | ||
restart_message_signalpolarity | 437B | msrc_UNKNOWN | Details | ||
simulate_level | 438B | Simulate | Simulate the Level reading of the device. | msrc_UNKNOWN | Details |
simulate_linlevelvolume | 438C | Simulate | Simulate the Linearized Level reading of the device. | msrc_UNKNOWN | Details |
simulate_ullage | 438D | Simulate | Simulate the Ullage reading of the device. | msrc_UNKNOWN | Details |
clear_all_simulated_diagnostics | 4294 | Clear Diagnostics Simulated | Clear all diagnostics simulated. | msrc_UNKNOWN | Details |
reset_level_trimming | 438E | Reset Level Trim | Reset the device level trim points to factory settings. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
lock_unlock_device | 1073 | Lock/Unlock device | Lock/Unlock Device- Places the device in either a locked or unlocked position. | msrc_UNKNOWN | Details |
device_self_test | 1071 | Self test | Self Test- Commands the electronics to perform a self test. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Device Reset- Commands the electronics to perform a reset. This is equivalent to cycling the power off and then back on to the field device. | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
device_variable_zero_trim | 1085 | Dev var zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
device_variable_trim | 1080 | Device variable trim | Device Variable Trim- Allows for the calibration measurement of a device variable to be adjusted linearly. The trim point that is sent to the device must represent the presently applied process variable value. | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
device_variable_trim_reset | 1083 | Device variable trim reset | Device Variable Trim Reset- Allows for the device variable to be set to its default factory trim. | msrc_UNKNOWN | Details |
fixed_analog_output | 1008 | Fix analog output | Fix Analog Output- Allows the User to manually manipulate a selected Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |