Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
zero_method | 40B0 | zero_method | Corrects the zero reading. | msrc_UNKNOWN | Details |
span_method | 40B1 | span_method | Corrects the reading to a known concentration of gas. | msrc_UNKNOWN | Details |
cal_entry_method | 40B2 | cal_entry_method | msrc_UNKNOWN | Details | |
cal_exit_method | 40B3 | cal_exit_method | msrc_UNKNOWN | Details | |
temp_trim_method | 40B4 | Correct Temp | msrc_UNKNOWN | Details | |
view_records_method | 40B5 | View Record(s) | msrc_UNKNOWN | Details | |
alarm_reset_method | 40B6 | Reset Alarms | Resets manual alarms that have returned to their reset point. | msrc_UNKNOWN | Details |
alarm_test_method | 40B7 | Test Alarms | Activates specified alarms - suspends normal operation. | msrc_UNKNOWN | Details |
alarm_test_abort_method | 40B8 | Abort Alarm Test | Ends all alarm tests on abort. | msrc_UNKNOWN | Details |
alarm_inhibit_method | 40B9 | Inhibit Alarms | Temporarily inhibits/reinhibits all alarms (including fault) for a specified period. | msrc_UNKNOWN | Details |
alarm_uninhibit_method | 40BA | End Inhibit | Clears the alarm inhibit timer and restores alarms to normal operation. | msrc_UNKNOWN | Details |
autotest_start_method | 40BB | Start Test | Performs one test cycle, leaves autotest setup unchanged. | msrc_UNKNOWN | Details |
autotest_stop_method | 40BC | Stop Test | msrc_UNKNOWN | Details | |
clear_faults_method | 4013 | Clear Faults | Clears faults (if possible). | msrc_UNKNOWN | Details |
reset_chgflag_method | 40BD | Reset Change Flag | Uploads the new transmitter configuration and resets the change flag. | msrc_UNKNOWN | Details |
clear_chgcnt_method | 40BE | Clear Change Count | msrc_UNKNOWN | Details | |
master_lock_method | 40BF | Set/Clr Lock | Guards configuration integrity by restricting access from operator interface panel and other masters (puts transmitter in Access Restricted mode). | msrc_UNKNOWN | Details |
pswd_lock_method | 40C0 | Set/Clr Pswd Lock | Guards configuration security by denying changes without entering correct password (puts transmitter in Write Protect mode). | msrc_UNKNOWN | Details |
pswd_change_method | 40C1 | Change Password | Change the password used to enable/disable write protect mode. | msrc_UNKNOWN | Details |
panel_access_method | 40C2 | Access Panel | Verifies locks are clear before allowing changes at the operator panel. | msrc_UNKNOWN | Details |
panel_reminder_method | 40C3 | msrc_UNKNOWN | Details | ||
squawk_method | 40C4 | Squawk | Causes transmitter to exhibit squawk display. Must touch ESC at transmitter panel or will timeout in one hour. | msrc_UNKNOWN | Details |
find_device_method | 40C5 | Find Device | Mode used to identify the transmitter. Must be armed at transmitter panel and will timeout in one hour. | msrc_UNKNOWN | Details |
memory_reset_method | 40C6 | Reset/Restart | Resets the selected memory region to factory default values and/or restarts the transmitter. | msrc_UNKNOWN | Details |
fault_recovery_method | 40C7 | Read Me! | Help to recover from a fault. | msrc_UNKNOWN | Details |
sensor_changegas_method | 40C8 | Change Gas | Permits selection of a new gas to monitor. | msrc_UNKNOWN | Details |
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
dac_trim | 1004 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |