Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
metAbort | 4000 | msrc_UNKNOWN | Details | ||
metZero | 4001 | Zero | Reset the gas reading to 0 (clean air for all gases except O2 and CO2). | msrc_UNKNOWN | Details |
metInhibit | 4003 | Inhibit mode | Set or clear inhibit mode. | msrc_UNKNOWN | Details |
metInhibitClr | 4002 | Clear Inhibit mode | Clear inhibit mode. | msrc_UNKNOWN | Details |
metPellCtrl | 4004 | Pellistor mode | msrc_UNKNOWN | Details | |
metPellSaverEnable | 4005 | msrc_UNKNOWN | Details | ||
metCrossCal_TargetGas | 4006 | msrc_UNKNOWN | Details | ||
metCal | 4009 | Calibration | Calibrate the gas reading to an applied gas level. | msrc_UNKNOWN | Details |
metTrim | 400D | Zero Trim | Trim analogue output 4mA point. | msrc_UNKNOWN | Details |
metSpan | 400F | Span Adjust | Span adjust analogue output to give 20mA with 100% target gas. | msrc_UNKNOWN | Details |
metRampClr | 400E | Clear ramp mode | Clear (exit) ramp mode. | msrc_UNKNOWN | Details |
metAuxRamp | 4010 | Ramp auxiliary method | Auxiliary method to assist with Ramp with and without alarm. | msrc_UNKNOWN | Details |
metRampNoAlarm | 4011 | Ramp No Alarm | Ramp (manual control) of analogue output for test without alarm relay activation. | msrc_UNKNOWN | Details |
metRampWithAlarm | 4012 | Ramp With Alarm | Ramp (manual control) of analogue output for test with alarm relay activation. | msrc_UNKNOWN | Details |
metTimeDateSet | 4013 | Date and Time | Set time and date in instrument. | msrc_UNKNOWN | Details |
metAlmAck | 4014 | Acknowledge Alarms | Reset latched alarms. | msrc_UNKNOWN | Details |
metBumpTerminate | 4015 | msrc_UNKNOWN | Details | ||
metBumpSpeedyTest | 4016 | Speedy Bump | Check alarm 1 can be exceeded in test time; use Abort to terminate purge when in clean air. | msrc_UNKNOWN | Details |
metBumpSmartTest | 4017 | Smart Bump | Check gas level between defined limits at end of test; use Abort to terminate purge when in clean air. | msrc_UNKNOWN | Details |
metBumpTest | 4018 | msrc_UNKNOWN | Details | ||
metSetInhibitMode | 4019 | Set | Inhibit loop current and alarm relays. | msrc_UNKNOWN | Details |
metClrInhibitMode | 401A | Clear | Remove inhibit of loop current and alarm relays. | msrc_UNKNOWN | Details |
metRelayTestTerminate | 401B | msrc_UNKNOWN | Details | ||
metRelayTest | 401C | Relay Test | Test alarm and fault relays. | msrc_UNKNOWN | Details |
metReset | 401D | Device Reset | Reset XgardIQ and perform all power-on tests. | msrc_UNKNOWN | Details |