Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
AckDidCnfgChksumChg | 4002 | Ack config changed | msrc_UNKNOWN | Details | |
AckDidColdStart | 4004 | Ack config lost | msrc_UNKNOWN | Details | |
AckDidPowerFail | 4005 | Ack power failure | msrc_UNKNOWN | Details | |
AckIs1BitMemoryError | 4006 | Ack memory error | msrc_UNKNOWN | Details | |
AckIsAnyKeyAboutToExpire | 4008 | Ack key(s) will expire | msrc_UNKNOWN | Details | |
AckIsAnyKeyExpired | 4009 | Ack key(s) expired | msrc_UNKNOWN | Details | |
AckIsCorePresent | 400A | Ack core file present | msrc_UNKNOWN | Details | |
AckWatchDogReset | 400B | Ack watchdog reset | msrc_UNKNOWN | Details | |
FO1KFactorMethod | 400C | Display K-factor | This displays the calculated K-factor and inverse K-factor for frequency output 1 based on the displayed maximum frequency and upper range | msrc_UNKNOWN | Details |
FO2KFactorMethod | 4013 | Display K-factor | This displays the calculated K-factor and inverse K-factor for frequency output 2 based on the displayed maximum frequency and upper range | msrc_UNKNOWN | Details |
AO1ContentPostEditMethod | 4017 | AO1 Content Changed | msrc_UNKNOWN | Details | |
AO2ContentPostEditMethod | 4001 | AO2 Content Changed | msrc_UNKNOWN | Details | |
Freq1ContentPostEditMethod | 4018 | Freq1 Content Changed | msrc_UNKNOWN | Details | |
Freq2ContentPostEditMethod | 4019 | Freq2 Content Changed | msrc_UNKNOWN | Details | |
UnitsChangedPostEditMethod | 401A | Units Changed | msrc_UNKNOWN | Details | |
StartZeroMethod | 401B | Start Zero | Start zero flow calibration | msrc_UNKNOWN | Details |
AbortZeroMethod | 401D | Abort Zero | Abort zero flow calibration | msrc_UNKNOWN | Details |
EndZeroMethod | 4020 | End Zero | End zero flow calibration | msrc_UNKNOWN | Details |
warning_message | 1017 | Ajustar malha para manual | msrc_UNKNOWN | Details | |
transmitter_dac_trim | 1024 | Start AO2 trim | Digital para ajuste analógico- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Restaurar o dispositivo | Restaurar dispositivo – comanda os eletrônicos para realizar a restauração. Esse equivalente ao ciclo de energia desligada e então retorne para o dispositivo de campo. | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Deixar o modo fixado atual | Modo atual de deixar fixado- Leva uma saída analógica para fora do modo onde a saída foi um valor constant, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |