Loading…

Method Name: epm_adjustment_method

Method ID: 0x467F

Method Label: EPM Adjustment

Method Help: Supports configuration of balanced pressure for the EPM module when you change the AVP700's positioner action.


  • {
  • char status[3];
  • int choice;
  • _set_all_resp_code(0);
  • _set_xmtr_all_resp_code(0);
  • _set_device_status(0xFF,0);
  • _set_xmtr_device_status(0xFF,0);
  • send_trans(164,1,status);
  • if (status[0])
  • {
  • display_response_status(164,status[0]);
  • DELAY(3,literal_string(1650));
  • process_abort();
  • }
  • if (ope_authority_sts != 1)
  • {