Loading…

Variable Name: device_status

Variable ID: 0x0097

Variable Label: Device status

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 PV Analog Channel Saturated
0x0008 PV Analog Channel Fixed
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
134 408A read_prom_id
176 408B read_low_flow_cut
178 40BA read_remote_seal_height
180 408D read_meter_config
182 408F read_limit_value
184 4091 read_de_conf
188 4093 read_alarm_config
190 4095 read_status_record
194 4098 read_zero_correct_record
198 4099 read_alarm_state
200 409A read_user_define_unit
202 409C read_system_para
208 409D read_contact_output_conf
214 40A1 read_write_protect
216 40A3 read_fw_sw_ver
220 419B read_press_freq_index
222 419D read_press_freq_sensor_select
224 419F read_press_freq_diag_config
226 41A1 read_press_freq_diag_alarm_config
228 41A3 read_overload_count
230 41A5 read_overload_config
232 41A7 read_overload_alarm_config
234 41A9 read_standard_deviation
236 41AB read_standard_deviation_config
238 41AD read_standard_deviation_alarm_config
240 41AF read_production_number
242 41B0 read_device_status
244 41B1 read_device_status_records
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
9 00DD read_device_variables_and_status
7 00DB read_loop_configuration
8 00DC read_dynamic_variable_classification
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
12 00B4 read_message
13 00B5 read_tag_descriptor_date
16 00B8 read_final_assembly_number
20 00DE read_long_tag
48 1043 read_additional_device_status
48 1043 read_additional_device_status
33 1054 read_device_variables
95 11DD read_device_communication_statistics

Variable Write Command List

None