Loading…

Variable Name: var_ds_fErrorCurrent

Variable ID: 0x4043

Variable Label: Error Current Value

Variable Help: Error Current Value Here you define the fault current in mA, if you have selected Value in the "Loop Alarm Type" parameter. If you have selected High or Low, then the appropriate current value is displayed here. If you exceed the mA value, then Value is set in the "Loop Alarm Type" parameter.

Variable Handling: R/W

Variable Class: AnalogOut

Variable Size: 4

Variable DataType: Float

Variable Display Format: |en|.2f

Variable Edit Format: |en|.2f

Variable Unit:

Variable Max:

Variable Min:

Variable Read Command List

Command Number Command ID Command Name
175 4211 cmd_rd_alarm_setup

Variable Write Command List

Command Number Command ID Command Name
177 4213 cmd_wr_alarm_code