Variable Name: device_status

Variable ID: 0x0097

Variable Label:

Variable Help: Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process

Variable Handling: R/W

Variable Class: Dynamic | Diagnostic | HART

Variable Size: 1

Variable DataType: BitEnum

Variable Enum Value Variable Enum Text
0x0001 Process applied to the primary variable is outside the operating limits of the field device
0x0002 Process applied to the non-primary variable is outside the operating limits of the field device
0x0004 Analog output 1 and its digital representation are outside the operating range limits, and not responding to input
0x0008 Analog output 1 and its digital representation are in fixed mode, and not responsive to input changes
0x0010 Field device has more status available
0x0020 A reset or self test of the field device has occurred, or power has been removed and reapplied
0x0040 A modification has been made to the configuration of the field device
0x0080 Field device has malfunctioned due to a hardware error or failure

Variable Display Format:

Variable Edit Format:

Variable Unit:

Variable Max: N/A

Variable Min: N/A

Variable Read Command List

Command Number Command ID Command Name
128 4084 read_pv_for_display
129 4085 read_tv_fv_display
130 4086 read_characterize_meter
131 4087 read_thermometer
132 4088 read_thermometer_range_data
133 4089 read_thermometer_liquid_mass
134 408A read_detector_number
144 4149 read_temp_current_and_percent_range
145 4093 read_span_unit_data
146 4094 read_density_data
147 4095 read_temperature_data
148 4096 read_dens_ratio_calc_data
149 4097 read_special_unit_data
150 414A read_v_data1
151 414B read_v_data2
152 414C read_v_data3
153 414D read_v_data4
154 414E read_v_data5
164 40A0 read_test_frequency_in
165 40A1 read_analog_output_data
166 40A2 read_contact_output_data
167 40A3 read_display_mode
168 40A4 read_total_mode
169 40A5 read_out_value
185 40B4 read_lowcut_flowrate
186 40B5 read_transmitter_adjust_data
187 40B6 read_flow_adjust_frequency
188 40B7 read_flow_adjust_data
189 40B8 read_transmitter_maintenance
190 40B9 read_transmitter_check
191 40BA read_dsp_data
192 40BB read_extra_data
193 4150 read_warning
208 4152 read_output_high_vibration
242 4168 read_maxband_mode
244 416A read_sensitibity
246 4154 read_v_vortex_freq
248 40C9 read_joker_password_log
249 40CA read_passwords_for_wrt_protect
252 416E read_select_hart_univ_rev
240 4170 read_test_auto_release_time
0 00AE read_unique_identifier
1 00AF read_pv
2 00B0 read_pv_current_and_percent_range
3 00B1 read_dynamic_variables_and_pv_current
12 00B4 read_message
13 00B5 read_tag_descriptor_date
14 00B6 read_pv_sensor_info
15 00B7 read_pv_output_info
16 00B8 read_final_assembly_number
48 0FCE read_additional_transmitter_status
110 1001 read_all_dynamic_variables

Variable Write Command List