0 |
ISC202 |
1 |
Warning: not applicable |
2 |
|
3 |
Burn is deactivated |
4 |
Soft-fail active |
5 |
HOLD is active |
6 |
E2 Temp. coeff. incorrect |
7 |
E3 Calibration out of limits |
8 |
E4 Temp. matrix make no sense |
9 |
E5 Conductivity too high |
10 |
E6 Conductivity too low |
11 |
E7 Temperature sensor open |
12 |
E8 Temperature sensor shorted |
13 |
E9 Air set not possible |
14 |
E10 EEprom write failed |
15 |
E15 Temperature adjust not possible |
16 |
E17 Output span too small |
17 |
E18 Table values not acceptable |
18 |
E19 Programmed values outside limits |
19 |
E20 Not initialized instrument |
20 |
E21 EEprom read error |
21 |
g |
22 |
dummy float |
23 |
dummy_3integer_value |
24 |
8u |
25 |
dummy_transfer_func |
26 |
The conductivity value that changes magnitude with respect to time with no user intervention. |
27 |
µS |
28 |
mS |
29 |
5.1f |
30 |
4.0f |
31 |
5.3f |
32 |
5.2f |
33 |
Uncomp. |
34 |
Conductivity value without temperature compensation. |
35 |
5.3e |
36 |
.1f |
37 |
Ref.Temp. |
38 |
Reference temperature used for temp. compensation |
39 |
TC1 perc |
40 |
Temperature compensation percentage 1 |
41 |
.2f |
42 |
4.2f |
43 |
TC2 perc |
44 |
Temperature compensation percentage 2 |
45 |
Conc. % |
46 |
Concentration percentage |
47 |
CC |
48 |
/cm |
49 |
Cell constant |
50 |
Sens.off. |
51 |
Sensor offset (value measured during AIRCAL) |
52 |
10.3e |
53 |
Hold fix |
54 |
mA-output value when Hold-Fixed selected |
55 |
4.1f |
56 |
Err.5 |
57 |
Error message configuration. Soft fail will give a flashing FAIL flag. Hard fail will give a steady FAIL flag and, when enabled an updated mA-output value |
58 |
Soft fail |
59 |
Hard fail |
60 |
Err.6 |
61 |
Err.7 |
62 |
Err.8 |
63 |
0% |
64 |
mA-output table 0% value (4.0 mA) |
65 |
5% |
66 |
mA-output table 5% value (4.8 mA) |
67 |
10% |
68 |
mA-output table 10% value (5.6 mA) |
69 |
15% |
70 |
mA-output table 15% value (6.4 mA) |
71 |
20% |
72 |
mA-output table 20% value (7.2 mA) |
73 |
25% |
74 |
mA-output table 25% value (8.0 mA) |
75 |
30% |
76 |
mA-output table 30% value (8.8 mA) |
77 |
35% |
78 |
mA-output table 35% value (9.6 mA) |
79 |
40% |
80 |
mA-output table 40% value (10.4 mA) |
81 |
45% |
82 |
mA-output table 45% value (11.2 mA) |
83 |
50% |
84 |
mA-output table 50% value (12.0 mA) |
85 |
55% |
86 |
mA-output table 55% value (12.8 mA) |
87 |
60% |
88 |
mA-output table 60% value (13.6 mA) |
89 |
65% |
90 |
mA-output table 65% value (14.4 mA) |
91 |
70% |
92 |
mA-output table 70% value (15.2 mA) |
93 |
75% |
94 |
mA-output table 75% value (16.0 mA) |
95 |
80% |
96 |
mA-output table 80% value (16.8 mA) |
97 |
85% |
98 |
mA-output table 85% value (17.6 mA) |
99 |
90% |
100 |
mA-output table 90% value (18.4 mA) |
101 |
95% |
102 |
mA-output table 95% value (19.2 mA) |
103 |
100% |
104 |
mA-output table 100% value (20.0 mA) |
105 |
Matrix T1 |
106 |
Matrix 1st temperature |
107 |
Matrix T2 |
108 |
Matrix 2nd temperature |
109 |
Matrix T3 |
110 |
Matrix 3rd temperature |
111 |
Matrix T4 |
112 |
Matrix 4th temperature |
113 |
Matrix T5 |
114 |
Matrix 5th temperature |
115 |
Matr.sel |
116 |
Selecting predefined matrix for temperature compensation |
117 |
H2S04 0.5-5% |
118 |
H2S04 2.5-25% |
119 |
HCl 0.5-5% |
120 |
HCl 1-20% |
121 |
HNO3 0.5-5% |
122 |
HNO3 2.5-25% |
123 |
NaOH 0.5-5% |
124 |
NaOH 0.5-15% |
125 |
Free |
126 |
M1_1 |
127 |
Matrix 1st value at 1st temperature |
128 |
M1_2 |
129 |
Matrix 2nd value at 1st temperature |
130 |
M1_3 |
131 |
Matrix 3rd value at 1st temperature |
132 |
M1_4 |
133 |
Matrix 4th value at 1st temperature |
134 |
M1_5 |
135 |
Matrix 5th value at 1st temperature |
136 |
M2_1 |
137 |
Matrix 1st value at 2nd temperature |
138 |
M2_2 |
139 |
Matrix 2nd value at 2nd temperature |
140 |
M2_3 |
141 |
Matrix 3rd value at 2nd temperature |
142 |
M2_4 |
143 |
Matrix 4th value at 2nd temperature |
144 |
M2_5 |
145 |
Matrix 5th value at 2nd temperature |
146 |
M3_1 |
147 |
Matrix 1st value at 3rd temperature |
148 |
M3_2 |
149 |
Matrix 2nd value at 3rd temperature |
150 |
M3_3 |
151 |
Matrix 3rd value at 3rd temperature |
152 |
M3_4 |
153 |
Matrix 4th value at 3rd temperature |
154 |
M3_5 |
155 |
Matrix 5th value at 3rd temperature |
156 |
M4_1 |
157 |
Matrix 1st value at 4th temperature |
158 |
M4_2 |
159 |
Matrix 2nd value at 4th temperature |
160 |
M4_3 |
161 |
Matrix 3rd value at 4th temperature |
162 |
M4_4 |
163 |
Matrix 4th value at 4th temperature |
164 |
M4_5 |
165 |
Matrix 5th value at 4th temperature |
166 |
M5_1 |
167 |
Matrix 1st value at 5th temperature |
168 |
M5_2 |
169 |
Matrix 2nd value at 5th temperature |
170 |
M5_3 |
171 |
Matrix 3rd value at 5th temperature |
172 |
M5_4 |
173 |
Matrix 4th value at 5th temperature |
174 |
M5_5 |
175 |
Matrix 5th value at 5th temperature |
176 |
0% Weight |
177 |
The 0% weight indication value |
178 |
.0f |
179 |
3.0f |
180 |
100% Weight |
181 |
The 100% weight indication value |
182 |
Sec. |
183 |
Second value in transmitter |
184 |
2.0f |
185 |
Min. |
186 |
Minute value in transmitter |
187 |
Hrs. |
188 |
Hour value in transmitter |
189 |
Day. |
190 |
Day value in transmitter |
191 |
Mth. |
192 |
mth_unit |
193 |
Month value in transmitter |
194 |
Yr. |
195 |
year_unit |
196 |
Year value in transmitter |
197 |
Maintenance |
198 |
Passcode for maintenance level in ISC202 Possible values: 0, 111, 333, 777, 888, 123, 957, 331, 546, 847 |
199 |
Commissioning |
200 |
Passcode for commisioning access in ISC202 Possible values: 0, 111, 333, 777, 888, 123, 957, 331, 546, 847 |
201 |
Service |
202 |
Passcode for service access in ISC202 Possible values: 0, 111, 333, 777, 888, 123, 957, 331, 546, 847 |
203 |
E6 lim. |
204 |
Limit for E6 (Conductivity too low) |
205 |
E5 lim. |
206 |
Limit for E5 (Conductivity too high) |
207 |
Temp.sens |
208 |
Selection of the temperature compensation sensor |
209 |
30k NTC |
210 |
Pt1000 |
211 |
Auto.Ret |
212 |
When Auto-return is ON, the converter reverts to the measuring mode from anywhere in the configuration menu, when no button is pressed during the set time interval of 10 minutes |
213 |
Percent |
214 |
When Percent by weight is ON, the 0% and 100% points can be entered |
215 |
Burn func. |
216 |
Diagnostic error messages can signal a problem by sending the output signals upscale or downscale (22mA or 3.9mA). The Pulse burnout setting gives a 22mA signal for the first 30 seconds of an alarm condition. After the pulse the signal returns to normal to activate a latching alarm |
217 |
Pls |
218 |
Hold fnc. |
219 |
Enable or disable of the HOLD feature |
220 |
Hold type |
221 |
Sets the Hold function to Last measured value or Fixed value. |
222 |
Last |
223 |
Fixed |
224 |
Hold status |
225 |
Sets the mA-output of the instrument in hold. No influence from the process anymore The HOLD feature must first be enabled |
226 |
Temp.unit |
227 |
Celsius or Fahrenheit scales to suit user preference |
228 |
°C |
229 |
°F |
230 |
TC1 type |
231 |
Temperature compensation type (Disp 1) |
232 |
NaCl |
233 |
T.C. |
234 |
Matrix |
235 |
TC2 type |
236 |
Temperature compensation type (Disp 2) |
237 |
mA func. |
238 |
Linear output on primary process value when activated or a table function which allows the configuration of an output curve by 21 steps. |
239 |
PV-Linear |
240 |
PV-Table |
241 |
Fmt |
242 |
Format for displaying conductivity |
243 |
Automatic |
244 |
xxx.x µS/cm |
245 |
x.xxx mS/cm |
246 |
xx.xx mS/cm |
247 |
xxx.x mS/cm |
248 |
xxxx mS/cm |
249 |
month string |
250 |
Jan |
251 |
Feb |
252 |
Mar |
253 |
Apr |
254 |
May |
255 |
Jun |
256 |
Jul |
257 |
Aug |
258 |
Sep |
259 |
Oct |
260 |
Nov |
261 |
Dec |
262 |
logbook function |
263 |
Lgb1 Reset |
264 |
Lgb1 Read next item |
265 |
Lgb2 Reset |
266 |
Lgb2 Read next item |
267 |
logbook event nr |
268 |
logbook minute |
269 |
logbook hour |
270 |
logbook day |
271 |
logbook month |
272 |
logbook year |
273 |
logbook event code |
274 |
Powerup |
275 |
Powerdwn |
276 |
System |
277 |
Defaults |
278 |
Lgb.clr |
279 |
init |
280 |
L.R.V |
281 |
U.R.V |
282 |
Hld.on |
283 |
Hld.off |
284 |
Err.on |
285 |
Err.off |
286 |
Tmp.adj |
287 |
Aircal. |
288 |
Calibr. |
289 |
Reftemp |
290 |
T.C. 1 |
291 |
T.C. 2 |
292 |
logbook unit |
293 |
|
294 |
logbook value |
295 |
12.1f |
296 |
dummy byte |
297 |
The event Powerup to be enabled/disabled in logbook1 or logbook2 |
298 |
Off |
299 |
On.LGB1 |
300 |
On.LGB2 |
301 |
The event Powerdown to be enabled/disabled in logbook1 or logbook2 |
302 |
Systemerr |
303 |
The event system error to be enabled/disabled in logbook1 or logbook2 |
304 |
The event Default loaded to be enabled/disabled in logbook1 or logbook2 |
305 |
Lg.Erased |
306 |
The event Logbook erased to be enabled/disabled in logbook1 or logbook2 |
307 |
Lg.Init |
308 |
The event initialization to be enabled/disabled in logbook1 or logbook2 |
309 |
Low range |
310 |
The event new output low range value to be enabled/disabled in logbook1 or logbook2 |
311 |
High range |
312 |
The event new output high range value to be enabled/disabled in logbook1 or logbook2 |
313 |
Hold on |
314 |
The event Hold-on to be enabled/disabled in logbook1 or logbook2 |
315 |
Hold off |
316 |
The event Hold-off to be enabled/disabled in logbook1 or logbook2 |
317 |
Error on |
318 |
The event Error-on to be enabled/disabled in logbook1 or logbook2 |
319 |
Error off |
320 |
The event Error-off to be enabled/disabled in logbook1 or logbook2 |
321 |
Temp. adj |
322 |
The event temperature adjusted to be enabled/disabled in logbook1 or logbook2 |
323 |
The event Cell Constant changed to be enabled/disabled in logbook1 or logbook2 |
324 |
Air cal. |
325 |
The event Air calibration to be enabled/disabled in logbook1 or logbook2 |
326 |
Calibrate |
327 |
The event Calibration to be enabled/disabled in logbook1 or logbook2 |
328 |
Ref. temp |
329 |
The event Ref. temperature changed to be enabled/disabled in logbook1 or logbook2 |
330 |
Temp.coef1 |
331 |
The event Temperature coefficient 1 changed to be enabled/disabled in logbook1 or logbook2 |
332 |
The event Matrix code changed to be enabled/disabled in logbook1 or logbook2 |
333 |
Temp.coef2 |
334 |
The event Temperature coefficient 2 changed to be enabled/disabled in logbook1 or logbook2 |
335 |
Invalid selection |
336 |
All read |
337 |
rec. broke |
338 |
Reads transmitter status and reports any transmitter errors. |
339 |
Logbook1 |
340 |
Reads content of logbook 1 from the ISC202 transmitter |
341 |
Logbook2 |
342 |
Reads content of logbook 2 from the ISC202 transmitter |
343 |
Offline |
344 |
Logbook |
345 |
Logbook conf. |
346 |
Param.specific |
347 |
Temp.specific |
348 |
Temp.compensation |
349 |
Matrix table |
350 |
Output function |
351 |
mA-table |
352 |
User Interface |
353 |
Error prog. |
354 |
Display |
355 |
Passcodes |
356 |
Write variables |
357 |
FMU860 |
358 |
DT |
359 |
DVC |
360 |
FCX |
361 |
AS800 |
362 |
340T |
363 |
340C |
364 |
344 |
365 |
Siemens Micro K |
366 |
SITRANS L |
367 |
SIPAN PH |
368 |
SITRANS P |
369 |
75SMT |
370 |
UNIDELTA |
371 |
8320 |
372 |
SX5100 |
373 |
TSV175 |
374 |
DMU |
375 |
3780 |
376 |
BM70 |
377 |
Transmitter Busy. |
378 |
Hard-fail active |
379 |
No Errors |
380 |
Reading logbook 1
--please wait-- |
381 |
Lgb%{logbnr} Rec%{dsp}
Powerup
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
382 |
Lgb%{logbnr} Rec%{dsp}
Powerdown
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
383 |
Lgb%{logbnr} Rec%{dsp}
System error
Code: %[2d]{lrvalueint}
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
384 |
Lgb%{logbnr} Rec%{dsp}
Defaults loaded
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
385 |
Lgb%{logbnr} Rec%{dsp}
Logbook erased
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
386 |
Lgb%{logbnr} Rec%{dsp}
Initialized
Code: %[2d]{lrvalueint}
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
387 |
Lgb%{logbnr} Rec%{dsp}
Low range changed
%[8.1f]{lrvalue} uS
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
388 |
Lgb%{logbnr} Rec%{dsp}
High range changed
%[8.1f]{lrvalue} uS
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
389 |
Lgb%{logbnr} Rec%{dsp}
Hold on
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
390 |
Lgb%{logbnr} Rec%{dsp}
Hold off
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
391 |
Lgb%{logbnr} Rec%{dsp}
Error on
%[2d]{lrvalueint}
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
392 |
Lgb%{logbnr} Rec%{dsp}
Error off
%[2d]{lrvalueint}
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
393 |
Lgb%{logbnr} Rec%{dsp}
Temp. offset
%[5.1f]{lrvalue} °C
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
394 |
Lgb%{logbnr} Rec%{dsp}
Temp. offset
%[5.1f]{lrvalue} °F
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
395 |
Lgb%{logbnr} Rec%{dsp}
Cell Constant
%[6.3f]{lrvalue} /cm
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
396 |
Lgb%{logbnr} Rec%{dsp}
Air calibration
%[5.2f]{lrvalue} µS
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
397 |
Lgb%{logbnr} Rec%{dsp}
Calibration
%[6.3f]{lrvalue} /cm
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
398 |
Lgb%{logbnr} Rec%{dsp}
Ref. temperature
%[5.1f]{lrvalue} °C
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
399 |
Lgb%{logbnr} Rec%{dsp}
Ref. temperature
%[5.1f]{lrvalue} °F
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
400 |
Lgb%{logbnr} Rec%{dsp}
Temp. coeff.1
%[4.2f]{lrvalue} %
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
401 |
Lgb%{logbnr} Rec%{dsp}
Matrix code
%[1d]{lrvalueint}
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
402 |
Lgb%{logbnr} Rec%{dsp}
Temp. coeff.2
%[4.2f]{lrvalue} %
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
403 |
Lgb%{logbnr} Rec%{dsp}
Unknown/new event
%{lrday}-%{0}-%[04d]{lryear} %{lrhr}:%[02d]{lrmin}
Next record? |
404 |
All records read. |
405 |
Reading logbook 2
--please wait-- |